ASSEMBLY
The heating unit shall be mounted in the heater's neck. The end of the thread is provided with
a rubber seal. To ensure better tightness we recommend the screw joint being additionally
sealed with cannabis, a Teflon sealing tape or a mastic sealant (be careful
–
choose a mastic
sealant suitable for demountable joints). Tighten the element properly. If the cable bushing
is not directed upright down, loosen the 4 screws on the plastic cover bottom. Turn the cover
(not more than by 180°) to the desired position and re
-tighten the screws. Check whether
the live parts of the wiring do not touch. The sealing ring is mounted last on the metal body
The space in front of the connection fitting equal to the installation 50 mm must be
left free for the installation, etc.
A sealing ring is part of the heating unit package.
1)
Water heater
2)
Electrical heating unit TJ
3)
Sealing ring
Figure 3