Electrical installation
NOTE
Electrical installation and service must be car-
ried out under the supervision of a qualified
electrician, and in accordance with applicable
electrical safety regulations.
If the power cable is damaged it must be re-
placed by the manufacturer, its authorised
service agent or another qualified person, in
order to prevent a hazard.
The water heater is supplied with a power cable with
earthed plug for 1 phase installation (1 kW). 1 phase
installation provides the best service life for the immer-
sion heater.
If the power cable is damaged, it must be replaced
under the supervision of a qualified electrician.
The lowest point of the power cable should be below
the power socket when you connect the water heater
to the socket. This prevents any drops of water from
being led into the socket.
If 3 kW is required, the water heater must be connected
as a permanent installation (2x400V). For permanent
installation, the water heater is preceded by an isolator
(preferably with a signal lamp) with at least 3 mm
breaker gap. The existing power cable can be used if
the plug is cut off.
Electrical circuit diagram
Thermostat/temperature limiter
(FD1 )
Immersion heater (EB1 )
Setting thermostat
For best operating conditions, we recommend a setting
of 60 °C (max approx. 80 °C).
LEK
Approx. 60 °C
25
Eminent
GB