Energy labelling
NIBE
Supplier
ERS S40-350
Model
Average: -38.3
Cold: -75.3
Warm: -14.4
kWh/(m
2
year)
Specific energy consumption (SEC)
A
Energy efficiency class
RVU, Bidirectional
Declared typology
Variable speed drive
Type of drive
Regenerative
Type of heat recovery system
83
Thermal efficiency of heat recovery
386
m
3
/h
Maximum air flow rate
161
W
Electric power input of the fan drive at maximum flow
rate
41
dB
Sound power level (LWA)
0.075
m
3
/s
Reference flow rate
50
Pa
Reference pressure difference
0.252
W/m
3
/h
Specific power input (SPI)
Local demand control (0.85)
Control factor and control typology
Internal: 2.8
External: 0.38
%
External leakage rates
See user manual.
Information about filter warning
See section
General ventilation connections
on page
Information about supply/exhaust grilles in the facade
See section
on page
.
This installer manual can also be accessed at
.
Information about pre-/disassembly
Average: 273
Cold: 810
Warm: 228
kWh/year
The annual electricity consumption
Average: 4,440
Cold: 8,686
Warm: 2,008
kWh
prim/year
Annual heating saved, kWh primary energy per year
NIBE ERS S40-350
Chapter 10 | Technical data
26