Charge pump
When the charge pump is connected to the terminal block
X11 (11) terminal 3 and 4 the pump is controlled by F2015.
Pump activity is dependent on the status of F2015, heat-
ing/hot water requirement and the outdoor temperature.
Pump exercising is handled by F2015.
Anti-freeze function
At temperatures below +2 °C, the charge pump runs period-
ically, and at temperatures below -20 °C it runs continually.
This function applies on the condition that F2015 is powered.
35
30
25
20
15
10
5
5
4
3
2
1
0
-1 -2 -3 -4 -5 -6 -7 -8 -9 -10 -11 -12 -13 -14 -15 -16 -17 -18 -19 -20 -21 -22 -23 -24 -25
0
0LQXWHV SHU PLQXWHV
7HPSHUDWXUH
NOTE
There is a risk of freezing when the charge pump is
connected to terminal block X11 (11) and F2015 is
deenergized.
FIGHTER 2020
EXTERNT
Signal vid icke larm
Signal vid larm
Laddpump
Extern värmekabel
N
N
230 V
3
4
1
X11
2
5
6
11
)
(;7(51$/
6LJQDO RQ
QRQDODUP
6LJQDOV LQ WKH
HYHQW RI DODUPV
&KDUJH SXPS
([WHUQDO KHDW
FDEOH
LEK
External heat cable
F2015 is equipped with a terminal block for the Condensation
water trough KVT 10 accessory. Max load is 200 W.
Outside sensor
An outdoor sensor (15) is located on the underside of F2015.
F2015
14
For the Installer
Electrical connections
Summary of Contents for F2015
Page 1: ...INSTALLATION AND MAINTENANCE INSTRUCTIONS MOS GB 1008 3 F2015 031239 F2015 LEK ...
Page 2: ......
Page 27: ...Electrical circuit diagram 1x230V 6 11 kW 25 F2015 Miscellaneous Electrical circuit diagram ...
Page 28: ...F2015 26 Miscellaneous Electrical circuit diagram ...
Page 29: ...27 F2015 Miscellaneous Electrical circuit diagram ...
Page 30: ...F2015 28 Miscellaneous Electrical circuit diagram ...
Page 40: ...F2015 38 ...
Page 41: ...39 F2015 ...
Page 42: ...F2015 40 ...
Page 43: ......