background image

14

Electric wiring diagram GV-HR110

-

-

+

+

M1
M2
N

N

N

L

L

0-10V

0-10V

0-10V

0-10V

L

L

L

L

N

N

N

N

N

L

+5V

0V

Signal

08-04-2014

0V

+10V

-

-

+

+

Mains connection

1x230VAC, L-N-PE

Max: 13A

H2 and H3 Max.

load total 

1800W

Aux. relay R9

1x230V 50Hz

ONLY control current

Genvex

Humidistat

Potential-free

contact

must be used

Sensor Frost 

Sensor, extract air

Sensor, exhaust air

Sensor, fresh air

Sensor, supply air

Sensor Option

External stop

EC fan

Extract air

Blue

Yellow

EC fan

Supply air

Blue

Yellow

Water valve

EC fan

Extract air

ON/OFF

Bypass

Brown

Brown

Blue

Blue

Yellow/green

Yellow/green

Water valve

Belimo

Bypass

Humidity sensor

White
Red
Blue

EC fan

Supply air

Aux. relay R8

1x230V 50Hz

ONLY control current

Red - Brown
Blue - Green
Yellow - White

Belimo

Bypass

Electric Reheater

Electric Preheater

Black

Black

White

White

12

3

H

y≥

S

et

12

3

1

2

1

2

H1

1
2

1
2

H2

1
2

1
2

H3

1
2

1
2

H6

1
2

1
2

H7

1
2
3

1
2
3

H8

1
2

1
2

H9

1
2

1
2

H

16

1
2

1
2

H

17

L

1
2

1
2

L1

1
2
3
4

1
2
3
4

L2

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

L3

1
2
3
4

1
2
3
4

L4

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

L6

1
2

1
2

L8

1
2
3
4

1
2
3
4

L11

1
2
3
4

1
2
3
4

L17

M1

M1

M2

M2

M3

M3

M5

N

P1

PE

PE

PE

T1

T3

T4

T7

T8

T9

21
22
23
24

21
22
23
24

OPTIMA DESIGN

M4

M4

Subject to Technical Modifications of GV-HR110

Summary of Contents for GV-HR110

Page 1: ...k NIBE A S Sverigesvej 6 DK 6100 Haderslev Tlf 45 7353 2700 www NIBE dk NIBE AB Sweden Box 14 Hannabadsv gen 5 SE 285 21 Markaryd www NIBE eu INSTALLATIONS MANUAL Passive ventilation Heat recovery GV...

Page 2: ...tics 7 Insulating ducts in warm rooms 8 Reheating of the supply air 8 Electric installations 9 Control and settings of the facility 9 Optimal adjustment of the facility 9 Facility maintenance 10 Troub...

Page 3: ...a thermostat and an electric heating element that switches on when the temperature falls below 2 C IMPORTANT IMPORTANT IMPORTANT IMPORTANT 7 Set the amount of incoming 1 and outgoing air before using...

Page 4: ...r 10 El kasse 11 Kondensvandsbakke 12 Kondensvandsafl b 13 230V 50Hz 14 By pass 2 4 13 72 7 60 7 550 42 1014 24 32 1088 1056 550 135 280 4 Subject to Technical Modifications of GV HR110 GV HR110 Assem...

Page 5: ...in the picture A A Visible wall mountings Concealed wall mountings Cabinet assembly gummif dder som leveret ved vandret montage af maskinen skal de leverede gummif dder flyttes til positioner som anvi...

Page 6: ...he condensation drain side The waterseal must be airtight e g by bending a 15 mm copper pipe as a waterseal see the drawing on the left A reinforced water hose is attached between the drain connection...

Page 7: ...even thicker insulation to avoid warm air in the attic from heating the incoming air during the summer Make sure that the closures are tight where the exhaust air duct comes through the roof or throu...

Page 8: ...ated in menu 4 5 User menu and that the setpoint temperature is set in menu 4 8 Service Menu Recommended setpoint is 3 C Reheating of the supply air Since the counterflow heat exchanger cannot recycle...

Page 9: ...ectly mounted with a waterseal and that it is protected from frost Pour 1 litre of water into the condensation container and check that it flows unimpeded through the condensation drain pipe 5 Set all...

Page 10: ...the procedure both knobs must be turned one quarter turn clockwise to the right When the filter has been exchanged or cleaned by shaking them to remove most of the dirt the filter timer is set by pre...

Page 11: ...amage the plates The effect will no longer be optimal if the plates are damaged Fans Remember to switch of the power supply Check the fans in the fan wheel for dirt every third year The four outermost...

Page 12: ...st No incoming air to the residence Error Faulty fan Fouled incoming air filter Fouled outside air grid A fuse has blown on the circuit board No power supply to the facility No exhaust air from the re...

Page 13: ...Belimo Bypass 230VAC H7 R10 Fan extract air 230VAC H8 R12 ON OFF Bypass 2x230VAC H9 R10 Fan supply air 230VAC bypass H16 R8 AUX relay 230VAC max 20W H17 R9 AUX relay 230VAC max 20W 1 1 1 1 1 1 1 1 1 1...

Page 14: ...Brown Brown Blue Blue Yellow green Yellow green Water valve Belimo Bypass Humidity sensor White Red Blue EC fan Supply air Aux relay R8 1x230V 50Hz ONLY control current Red Brown Blue Green Yellow Wh...

Page 15: ...dards hergestellt Directive a Machinery 2006 42 EC 15 March 2006 b Low Voltage 2006 95 EU 12 December 2006 c Electromagnetic Compatibility 2004 108 EC 15 December 2004 d Radio Telecommunication 99 5 E...

Page 16: ...294 71 Benatky nad Jizerou Tel 420 326 373 801 Fax 420 326 373 803 E mail nibe nibe cz www nibe cz PL NL FI DK DE CZ NIBE Energy Systems OY Juurakkotie 3 01510 Vantaa 3C Broom Business Park Bridge Wa...

Reviews: