background image

 

 

EF - Försäkran om Överenstemmelse

 

EC - Declaration of Conformity 

EG - Konformitätserklärung

 

 

Intygar härmed att följande produkt / hereby certifies that the following product / bestätigt, da das nachfol-

gend bezeichnete Gerät:  

B. Beteckning  : 

  Type 

  Typ: 

:

C. Huvednr     :   

   S/N 

:

        

Nibe 

TM 

GV-HR110-250 

Nibe 

TM 

GV-HR110-250H 

Nibe 

TM 

GV-HR110-400 

Nibe 

TM 

GV-HR110-400H

 

066033, 066039, 066046, 066047, 912001, 912002 

Under forutsättning att Nibe Energy Systems monteringsanvisningar har följts

 

/ on the assumption that the 

mounting instructions from Nibe energy Systems have been followed / bei Voraussetzung dass die Montagean-

weisungen von Nibe Energy Systems gefolgt wurden 

Har tillverkats i överensstämmelse med / is made according to /  

über Einstimmung von nachfolgend bezeichnete EG-Sicherheitsstandards hergestellt: 

Directive: 

a) 

Machinery   

 

 

 

2006/42/EC 15. March 2006   

b) 

Low Voltage  

 

 

 

2006/95/EU 12. December 2006 

c) 

Electromagnetic Compatibility   

2004/108/EC 15. December 2004  

d) 

Radio/Telecommunication 

 

99/5/EC 9. March 1999 

e) 

RoHS  

   

 

 

2011/65/EU 8. June 2011 

 
 

Departmental Order. 

a) 

No. 797 17. August 2009  

b) 

LBK nr. 823 af 3. July 2007   

c) 

No. 743 af 23. September 1999 

d) 

AT No. 612 af 25. June 2008. 

 

DS/EN 

a)  

60335-1-A13-A14 General requirements 

b) 

60335-2-40  

Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers 

c) 

55014-1 

 

Electromagnetic compatibility Part 1: Emission

 

d) 

55014-2 

 

Electromagnetic compatibility Part 2: Immunity

   

 

 

 

 

 

Företag:

 

Company:

 

Firma:

 

 

 

Ort och datum:

 

Place and date:

 

Ort und Datum:

 

Underskrift:

 

Signature:

 

Unterschrift:

 

Nibe Energy Systems

 

Hannabadsvägen 5

 

SE-28521 Markaryd

 

Markaryd, 

 

22. November 2013

 

   
 
Peter Jocic                                   Kenneth Magnusson  

 

 

 

 

 

(PM Director)                                  (Quality Manager) 

 

15

CE-Manufacturing Assurance GV-HR110

Subject to Technical Modifications of GV-HR110

Summary of Contents for GV-HR110

Page 1: ...k NIBE A S Sverigesvej 6 DK 6100 Haderslev Tlf 45 7353 2700 www NIBE dk NIBE AB Sweden Box 14 Hannabadsv gen 5 SE 285 21 Markaryd www NIBE eu INSTALLATIONS MANUAL Passive ventilation Heat recovery GV...

Page 2: ...tics 7 Insulating ducts in warm rooms 8 Reheating of the supply air 8 Electric installations 9 Control and settings of the facility 9 Optimal adjustment of the facility 9 Facility maintenance 10 Troub...

Page 3: ...a thermostat and an electric heating element that switches on when the temperature falls below 2 C IMPORTANT IMPORTANT IMPORTANT IMPORTANT 7 Set the amount of incoming 1 and outgoing air before using...

Page 4: ...r 10 El kasse 11 Kondensvandsbakke 12 Kondensvandsafl b 13 230V 50Hz 14 By pass 2 4 13 72 7 60 7 550 42 1014 24 32 1088 1056 550 135 280 4 Subject to Technical Modifications of GV HR110 GV HR110 Assem...

Page 5: ...in the picture A A Visible wall mountings Concealed wall mountings Cabinet assembly gummif dder som leveret ved vandret montage af maskinen skal de leverede gummif dder flyttes til positioner som anvi...

Page 6: ...he condensation drain side The waterseal must be airtight e g by bending a 15 mm copper pipe as a waterseal see the drawing on the left A reinforced water hose is attached between the drain connection...

Page 7: ...even thicker insulation to avoid warm air in the attic from heating the incoming air during the summer Make sure that the closures are tight where the exhaust air duct comes through the roof or throu...

Page 8: ...ated in menu 4 5 User menu and that the setpoint temperature is set in menu 4 8 Service Menu Recommended setpoint is 3 C Reheating of the supply air Since the counterflow heat exchanger cannot recycle...

Page 9: ...ectly mounted with a waterseal and that it is protected from frost Pour 1 litre of water into the condensation container and check that it flows unimpeded through the condensation drain pipe 5 Set all...

Page 10: ...the procedure both knobs must be turned one quarter turn clockwise to the right When the filter has been exchanged or cleaned by shaking them to remove most of the dirt the filter timer is set by pre...

Page 11: ...amage the plates The effect will no longer be optimal if the plates are damaged Fans Remember to switch of the power supply Check the fans in the fan wheel for dirt every third year The four outermost...

Page 12: ...st No incoming air to the residence Error Faulty fan Fouled incoming air filter Fouled outside air grid A fuse has blown on the circuit board No power supply to the facility No exhaust air from the re...

Page 13: ...Belimo Bypass 230VAC H7 R10 Fan extract air 230VAC H8 R12 ON OFF Bypass 2x230VAC H9 R10 Fan supply air 230VAC bypass H16 R8 AUX relay 230VAC max 20W H17 R9 AUX relay 230VAC max 20W 1 1 1 1 1 1 1 1 1 1...

Page 14: ...Brown Brown Blue Blue Yellow green Yellow green Water valve Belimo Bypass Humidity sensor White Red Blue EC fan Supply air Aux relay R8 1x230V 50Hz ONLY control current Red Brown Blue Green Yellow Wh...

Page 15: ...dards hergestellt Directive a Machinery 2006 42 EC 15 March 2006 b Low Voltage 2006 95 EU 12 December 2006 c Electromagnetic Compatibility 2004 108 EC 15 December 2004 d Radio Telecommunication 99 5 E...

Page 16: ...294 71 Benatky nad Jizerou Tel 420 326 373 801 Fax 420 326 373 803 E mail nibe nibe cz www nibe cz PL NL FI DK DE CZ NIBE Energy Systems OY Juurakkotie 3 01510 Vantaa 3C Broom Business Park Bridge Wa...

Reviews: