18
POOL 11
GB
1. Install the edge protection on the sharp edge, see the
right image.
2. The supplied relay card (-E34) is installed on the exist-
ing relay card (-E29) using plastic turrets, see image
below.
3. Connect the edge connector wiring between the
supplied relay card (–E34) and relay card (–E29) as
illustrated below.
All electrical connections must be carried
out by an authorised electrician.
Electrical installation and wiring must be
carried out in accordance with the stipula-
tions in force.
Note!
Utan tillbehör
Electrical connection
M5, self-tapping
torx screws
–X6
HAHN
LEK
Relay card, –E34
Relay card, –E29
Edge board wiring
Utan tillbehör
Electrical
connection
–X6
Edge protection
–PE3
–E29
Room for
–E34
–E2
–X1
GT11
GT16
P3
SV4
4. The corresponding wiring with flat pin sleeves and
zero numbers 0110, 0101 and 0100 are installed as
follows:
- Brown (single) cable with zero number 0100 to
flat pin –E34:41.
- Brown cable with zero number 0100 and 0101 to
flat pin –E34:39.
- Brown cable with zero number 0101 and 0110 to
flat pin –E34:37.
- Brown (single) cable with zero number 0110 to
spring terminal –E29:X1b:17.
5. Install connection terminals, labels and strain relief on
the panel. Screw the plate into place with the three
accompanying M5 self-tapping screws, see image
below.
6. Press the 10-pin edge connector with zero number
0106, 0107 and 0102 on the relay card –E29 as
illustrated below (
Note!
Observe the guide pin in
the edge connector). Then install the loose ends as
follows:
- Blue cable with zero number 0106 to spring termi-
nal –X6:3.
- Brown cable with zero number 0107 to spring
terminal –X6:1.
7. Connect the other single cables as follows:
- Brown cable with zero number 0109 to spring
terminal –E29:X1b:16 and in spring terminal –
X6:2.
- Yellow/green cable with zero number 0108 to
spare connection on ground flat pin –PE3 see im-
age and in spring terminal–X6:4.
- Brown cable with zero number 0105 to flat pin –
E34:38 and in spring terminal –X6:5.
Electrical connection FIGHTER 1240/1250
-E29
Relay card
10-pin
connector
Only ESV21
Following cable for Pool 11 used in this kit:
0100, 0101, 0102, 0105, 0106, 0107, 0108, 0109,
0110.
Summary of Contents for POOL 11
Page 2: ......
Page 16: ...14 POOL 11...
Page 30: ...28 POOL 11...
Page 44: ...42 POOL 11...
Page 45: ...43 POOL 11 Elschema SE DE GB Wiring Diagram Elektrischer Schaltplan...
Page 47: ...45 POOL 11 Elschema Wiring Diagram Elektrischer Schaltplan FIGHTER 1235 1240 1250...
Page 48: ...46 POOL 11 Elschema Wiring Diagram Elektrischer Schaltplan FIGHTER 1235 1240 1250...
Page 49: ...47 POOL 11 Elschema Wiring Diagram Elektrischer Schaltplan FIGHTER 1220 1230...
Page 50: ...48 POOL 11 Elschema Wiring Diagram Elektrischer Schaltplan FIGHTER 1120 1130 1135 1140...
Page 51: ......