18 - ACCESSORY INPUTS AND OUTPUTS 

GATE OPERATOR ACCESSORY INPUTS:
Auxiliary Inputs 1 (16) and 2 (18):

 These digital inputs may be connected 

to the digital outputs of accessories and programmed to activate or control 

the gate operator in a number of different modes. Shorting the pins through a 

dry contact activates the programmed settings for these inputs. These inputs 

are programmed in the “FUNCTION Auxiliary I/O” menu. 

SAFETY LOOP Input:

 (22) Dry contact input that can be programmed for an 

inductive safety loop or photo-eye detector. Shorting pin 22 to GND reverses 

a closing gate to the full open position. The opened gate is held opened for 

as long as the LOOP input is active. 

SHADOW (LOOP 1) Input:

 (24) Dry contact input that can be programmed 

for an inductive safety loop or photo-eye detector. Shorting the LOOP 1 input 

(24) to GND maintains an OPEN gate fully open and a CLOSED gate fully 

closed until deactivated. 
Setting the LOOP1 input to “Photo Mode” causes the moving gate to stop, 

then reopens the gate when the LOOP1 input is deactivated. 

ENTRAPMENT (LOOP 2) Input:

 (26) Dry contact input that can be 

programmed for an inductive safety loop or photo-eye detector. Shorting the 

LOOP2 input (26) to GND while the gate is opening cause the gate to close 

to the fully closed position. This loop input is intended for use with safety 

sensors to prevent entrapment between the opening gate and an adjacent 

wall or structure. 

Edge Input:

 (28) This input may be configured as “DIGITAL” or “ANALOG” 

as required by the sensor type. When configured as “DIGITAL”, this is a dry 

contact input; otherwise when configured as “ANALOG”, the input must 

measure 8200ohms. When the input is activated it stops the gate regardless 

of direction of travel, momentarily reverses it then stops. 

Exit Input:

 (30) Dry contact input for a vehicle exit sensor. Shorting this 

input to GND opens gate from the closed position and holds gate open with 

maintained input or reverses gate if closing. 

Fire Input:

 (32) Dry contact input for a fire department control switch. Opens 

the gate and holds the gate open until the control switch is deactivated. This 

input is “hold to run”. Auto-close is disabled when this input is activated. Also 

clears hard shutdown. 

GUARD STATION
Guard Station Open:

 (34) Dry contact input for a guard station open switch. 

Momentarily shorting the digital input to GND opens the gate to the full open 

position with the subsequent auto-close feature enabled. 

Guard Station Stop:

 (35) Dry contact input (Normally Closed) for a guard 

station stop switch. Momentarily opening this input stops the opening gate at 

its current position. While this input is activated, all other inputs are disabled 

and are not functional. 

Guard Station Close:

 (36) Dry contact input for a guard station close 

switch. Momentarily shorting the digital input to GND closes the gate (master 

and slave). 

RADIO
Radio Open:

 (39) Dry contact input for an accessory radio open switch. 

Momentarily shorting the digital input to GND opens the gate to the full open 

position with the subsequent auto-close feature enabled. 

Radio Close:

 (40) Dry contact input for an accessory radio close switch. 

Momentarily shorting the digital input to GND closes the gate. 

Radio Input:

 Open/Close: (39 and 40) If you tie open and close together the 

unit will operate as a Step by Step command each time the input is shorted 

to GND, it will either OPEN, STOP or CLOSE.

18.1 - Outputs 

Figure - BOARD OUTPUTS 

GATE OPERATOR ACCESSORY OUTPUTS:
OUT1 and OUT2:

 Individual, isolated relays provide COMMON, NORMALLY 

OPEN, and NORMALLY CLOSED dry contacts for switching accessories 

based on programming of the “Auxiliary IO” function. These outputs are 

programmed in the “FUNCTION Auxiliary I/O” menu. 

Magnetic Lock:

 Provides fused power (1.85A max) and isolated relay 

COMMON, NORMALLY OPEN, and NORMALLY CLOSED dry contacts for 

electrically powered and maintained magnetic locks. The output time for 

magnetic lock activation/deactivation may be adjusted from 0 to 5 seconds. 

Lamp:

 Provides fused power (1.85A max) to drive a flashing warning lamp 

to indicate gate operation. This output is active when the gate is operating 

(Opening and Closing). Lamp Delay sets the amount of time the lamp 

accessory output is activated prior to gate movement. Settings from 0 to 5 

seconds with a step of 0.5 seconds. 

Alarm:

 Provides fused power (0.5A @ 12VDC) to drive an alarm siren 

to signal the occurrence of a hard shutdown, caused by 2 consecutive 

entrapment events (signals). This alarm output is reset by pressing the “Reset 

Hard Shutdown” button on the front panel or activating the “FIRE” input. 

18.2 - Inputs 

Figure - INPUTS 

Summary of Contents for H12-ETL-1K

Page 1: ...Nice Apollo Swing Gate Opener Vehicular Swing Gate Operator Revision 1 0 0 0_2 2014 Model H12ETL 1K...

Page 2: ......

Page 3: ...ION 10 11 CONTROL BOX MOUNTING 11 12 MOTOR WIRING 11 13 LIMIT AND MOTOR CONNECTION TO THE BOARD 11 14 INCOMING POWER WIRING 12 15 LIMIT SWITCH ADJUSTMENT 13 16 REPLACE COVER 13 17 LEARNING MODE 14 18...

Page 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Page 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Page 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Page 7: ...nt any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of t...

Page 8: ...IDENTIFICATION Accessory Output Connections Power Input Connections Motor Output Connections BlueBus Connection Master Slave Connection Accessory Input Connections Control Box 11111B Earth Ground H12...

Page 9: ...size or hinge location Remove the cover from the motor assembly and store in a safe place with screws Remove motor assembly from the mounting bracket B A 17 3 4 B A inches 3 9 16 4 5 16 6 7 7 8 9 13 1...

Page 10: ...ly Disengage the manual release as shown With the gate in the closed position push the arm towards the gate as shown Tack weld or C clamp the gate bracket in place Permanent welds or bolts should be c...

Page 11: ...k green limit common yellow motor encoder signal blue common orange open limit switch white close limit switch 12 MOTOR WIRING Mount the control box within 4 feet of the motor assembly Do not mount th...

Page 12: ...onnect wires to the battery terminal block The positive wire of the battery connects to the left terminal marked Note If the battery is connected backwards a red LED will illuminate below the terminal...

Page 13: ...of the Control board hold the button down until the gate reaches the fully intended open position Adjust the Open Limit Switch until the GREEN light illuminates on the front of the control board The F...

Page 14: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Page 15: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Page 16: ...cting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receive...

Page 17: ...d for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 re...

Page 18: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 21 2 Magnetic lock connection...

Page 19: ...ty equipment and connections Clean equipment and connections 22 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 22 7 Poor mechan...

Page 20: ...Photocells Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Figure LAYOUT FOR PHOTOCELLS Loop Safety Loop Safety Loop Shadow Loop Exit...

Page 21: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Page 22: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Page 23: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 26 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Page 24: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Page 25: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Page 26: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Page 27: ...27 1 1 2 2 A A B B COMPANY NICE APOLLO NAME CONTROL BOX GENERAL OVERVIEW 18 22 18 18 8 32...

Page 28: ...LE POLE 1115 1 4 SWITCH PUSH BUTTON CNTRL BOX 1119 1 5 1050 CIRCUIT BOARD 1050 1 6 1050 BOARD MOUNT KIT 10055090 1 7 NICE RECEIVER 318NPI 1 8 1 1 2 2 A A B B TITLE Company 2 6 8 3 7 4 5 1 Note Control...

Page 29: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Page 30: ...30...

Page 31: ...e and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has...

Page 32: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...

Reviews: