21
OVIEW (see page 6 for Picture of OVIEW)
Programming and diagnostic unit which connects directly to the gate controller and is part
of the Nice “Opera” control system. The unit can be used in “stand-alone” mode via its
front-panel keypad, or it may be accessed via a Bluetooth or cellular-enabled PDA, PC, or
Smartphone when used with the O-View Software Suite. This unit, when matched with the
OVIEW Bluetooth or GSM modules, enables remote control and management of the gate
controller. Remote control functions include most of the programming functions that are
available at the front panel LCD on the control board as well as software updates.
OVBT:
Bluetooth module for OVIEW and the “O-View Software Suite” application for PC,
PDA, or Smartphone for localized wireless control of the gate controller.
OVBTGSM:
Combination GSM and Bluetooth module that plugs into the OVIEW and
provides cellular phone access through the “O-View Software Suite” application for PC,
PDA, or Smartphone, for wireless local, national, and international controller of the gate
controller.
O-VIEW Software Suite:
Provides desktop or Smartphone level control of the gate
controller. Other benefits include software updates that can be made wirelessly as new
versions of software are made available.
4.2.3 - OVIEW REMOTE CONTROL
5 - WIRING AND CONNECTIONS
Use only U.L. listed (or equivalent) non-contact sensors. Inputs from the photo beam to the
circuit board are Normally Open (N.O.). Use only U.L. listed (or equivalent) non-contact
sensors. Connect the non-contact sensors. Photo-beam input shall REVERSE travel of
gate when activated during the CLOSE CYCLE ONLY. Gate will resume normal operation
when photo-beam is no longer activated.
To reduce the risk of SEVERE INJURY or DEATH:
Disconnect power to the gate operator by manually opening its dedicated circuit breaker
before making any mechanical or electrical adjustments.
All wiring connections MUST be made by a qualified individual.
Run individual circuits in separate U.L. listed conduits. Do not combine high voltage
(120VAC) power wiring and low voltage (+12VDC to +24VDC) control wiring in the same
conduits.