background image

Page 3 

www.hysecurity.com

    © 2017 

P/N MX3114  D0584 Rev E

StrongArmPark DC: Lighting Connection for Articulated Arm

1.  Make sure both AC and DC power switches are turned OFF. 
2.  Insert leads of wire harness through the hole in chassis between the two bracket mounts. Feed the 

cable through the interior of the chassis. Pull enough cable to reach the Smart DC Controller terminals.

NOTE:

 Connect wire lead to 24VDC. Lights are dim when connected to 12VDC.

3.  Attach the end of the wire harness (on the outside of the chassis) to the LED light connector on the 

arm. The wire harness connector is keyed. Be sure to seat the connectors before threading close.

CAUTION

 

To allow full arm travel, the cable loop on the outside of the chassis must be a minimum 8-inches (20 cm) in length.

4.  Secure the harness to the chassis with the strain relief bushing.  

DC Power 

Switch

AC Power 

Switch

Remove center plug 

to feed wire harness 

cable through 

chassis.

Remove smaller 

plugs to mount 

articulating arm 

strut.

LED Arm Light 

connector

 Wire harness   

 connector

Connect Articulating Arm Cable

Secure cable 

with strain relief 

bushing. 

Cable loop length: 

8-inches (20 cm)

Feed Cable through Chassis

Remove Plugs in Chassis

Summary of Contents for HySecurity StrongArmPark DC Series

Page 1: ... 7 16 and 9 16 inch Drill bit 9 32 inch 1 4 inch Hex key For detailed views of the assembly see page 2 Breakaway bracket and Mounting bracket assembly described in StrongArmPark DC Quick Start Steps MX3651 01 If the tip of the arm droops or angles up too much level the arm by tightening or loosen the linkage fasteners that secure the rod ends Rod end Rod end Arm cap Tip of the arm 1 4 inch fastene...

Page 2: ...own Technical Support For technical support call your installer or authorized HySecurity distributor Obtain the serial number of your operator before calling For the name of a distributor near you call HySecurity at 800 321 9947 12 1 12 2 12 3 Drill 9 32 inch mounting holes 1 4 inch fasteners provided Arm lights connection Arm lights connection ...

Page 3: ...outside of the chassis to the LED light connector on the arm The wire harness connector is keyed Be sure to seat the connectors before threading close CAUTION To allow full arm travel the cable loop on the outside of the chassis must be a minimum 8 inches 20 cm in length 4 Secure the harness to the chassis with the strain relief bushing DC Power Switch AC Power Switch Remove center plug to feed wi...

Page 4: ...ves battery life COM COM COM COM COM COM COM COM STOP OPEN RADIO CLOSE OPEN OPEN P ARTIAL EYE OPEN EYE CLOSE EXIT LOOP BLOCK EXIT INOBS LOOP OUTOBS LOOP CENTER LOOP EDGE EYE COM 24V EMERG OPEN SHOW LEDs U S ER2 COM NO DC USERRELAY1 Electro mechanical USERRELAY2 Solidstate 24VDC 24VDC 12VDC 12VDC See CAUTION EDGE 24V OPEN COM DUAL GATE COM B A R2 28 FLASH AC RELAY 2 LOGIC OPEN CLOSE STOP MENU RESET...

Reviews:

Related manuals for HySecurity StrongArmPark DC Series