English
English –
3
––– STEP 5 –––
Maintenance must be performed in strict observance of the safety
provisions in this manual and according to current legislation and
standards.
The automation devices do not require special maintenance. However a
check should be performed at least every six months to ensure complete
efficiency of all devices.
For this purpose, the tests and checks envisaged in paragraph 4.1
“Testing” should all be performed, as well as all procedure in the para-
graph “Maintenance operations permitted for the user”.
If other devices are present, follow the instructions in the relative mainte-
nance schedule.
If the motor is replaced, it is possible to use the replacement pin and
move the gate manually: to insert the pin see
Fig. 21
.
MAINTENANCE
This product is an integral part of the automation and therefore
must be disposed together with the latter.
As in installation, also at the end of product lifetime, the disassembly and
scrapping operations must be performed by qualified personnel.
This product is made of various types of material, some of which can be
recycled while others must be scrapped. Seek information on the recy-
cling and disposal systems required by local regulations in your area for
this product category.
Warning!
– some parts of the product may contain pollutants or hazard-
ous substances which, if disposed of in the environment, may cause seri-
ous damage to the environment or physical health.
As indicated by the symbol alongside, disposal of this
product in domestic waste is strictly prohibited. Sepa-
rate the waste into categories for disposal, according to
the methods set out by legislation in force in your area, or
return the product to the retailer when purchasing a new
version.
Warning!
– Local legislation may provide for severe fines for improper
disposal of this product.
PRODUCT DISPOSAL
TECHNICAL SPECIFICATIONS OF PRODUCT COMPONENTS
IN100 is manufactured by NICE S.p.A. (prov. of Treviso – Italy). Nice S.p.A., in order to improve its products, reserves the right to modify their technical
specifications at any time without prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
Note: all technical specifications refer to a temperature of 20°C.
Control Unit
IN100
Type
Electro-mechanical dear motors for gates and doors with hinged panels
Power input:
24 V
Nominal absorption
1 A
Maximum absorption
2.9 A
Nominal power
25 W
Maximum power
70 W
Protection rating
IP 67
Run
0°...120° (±10°)
Nominal speed
1.5 rpm
Nominal torque
60 Nm
Maximum torque
150 Nm
Functioning temperature
-20°C...+50°C
Cycles/hour at the nominal torque
60
Dimensions
305 x 145 x 346
Weight (kg)
5.5