background image

English – 

3

-S

+

-

+

10
11
12
13

2

ATTENTION

: If two photoelectric barriers are used as an anti-entrapment 

safeguard, the relay contacts (opening contacts) of the receivers must be 
switched in series and connected at terminal J33 on the main board of the 
D-PRO Automatic Door Control.

1
2
3
4
5

3

6
7
8
9

4

CE Declaration of Conformity

Declaration is in agreement with the following directives: 2006/95/CE (LVD) EN 60335-1:2012, 2004/108/CE (EMC), 2006/42/CE (MRL)

Note: The content of this Declaration of Conformity corresponds to the declaration at the last available version of the document of

fi

 cially 

fi

 led in the of

fi

 ces 

of Nice S.P.A. prior to the printing of this manual. This text has been adapted to meet editorial requirements. A copy of the original declaration may be 
requested from Nice S.P.A. (TV) I.

Name of manufacturer

: NICE S.p.A. 

Document

: 490/D-PRO AUTOMATIC Rev.01

Address

: Via Pezza Alta N°13, 31046 Rustignè di Oderzo (TV) Italy

Product type

: Industrial Door Control Nice

Model / Type

: Input and Relay Module K30 

 

It is hereby declared that the corresponding technical documentation was created in accordance with Appendix VII A of the directive 2006/42/EC.
For the storage location of the technical documentation, see address.

The undersigned Mauro Sordini, as Chief Executive Of

fi

 cer, hereby declares under his own responsibility that the product identi

fi

 ed above complies with 

the provisions of the following directives:

•  2006/42/EC DIRECTIVE OF THE EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006, machinery directive.
  The following harmonized standard was applied: EN ISO 13849: 2008.
  The safety functions: Monitoring of external safety elements (contact x6) Cat 2 PLd, end position monitoring Cat2 PLd,
  safety circuit/emergency stop Cat3 PLd. 

•  2006/95/EC DIRECTIVE OF THE EUROPEAN PARLIAMENT AND COUNCIL of 12 December 2006, in accordance with the following harmonised stand-

ards: EN 60335-1:2012 (low-voltage directive).

•  2004/108/EC DIRECTIVE OF THE EUROPEAN PARLIAMENT AND COUNCIL of 15 December 2004 in accordance with the following harmonised stand-

ards: EN 61000-6-2:2005, EN 61000-6-3:2007 (EMV directive)

•  EC type-examination certi

fi

 cate no. 44 205 13 405182 001 NB0044 

  TÜV NORD CERT GmbH, Langemarckstr. 20, 45141 Essen, Germany

Oderzo, 1 October 2013

 Mauro Sordini

(Chief Executive Of

fi

 cer)

Main board of

D-PRO Automatic

Add-on module

K30

Main board 

of D-PRO Automatic

Receiver 2

Transmitter 2

Transmitter 1

Receiver 1

Anti-entrapment photoelectric barrier 2 (internal)

X5

Ox

X6

24 V-DC

1/2UP

R6

R7

Anti-entrapment photoelectric barrier 1 (external)

R3

R1

R2

Red external

Green external

Green internal

Red internal

L1

Ox

Red 

external 

Green

N

Green 

internal 

Red

Connection for two-way traffi c light

Signalling of end positions UP and DOWN

Ox

R4

R5

Potential-free 1 up
(display of upper fi nal position)

Potential-free 2 down
(display of lower fi nal position)

EN

Summary of Contents for M01 Series

Page 1: ...installazione e l uso FR Instructions et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalación y el uso PL Instrukcje i ostrzeżenia do instalacji i użytkowania NL Aanwijzingen en aanbevelingen voor installatie en gebruik Input and Relay Module K30 Industrial D Pro Automatic ...

Page 2: ... the system during installation The packaging material of the door control must be disposed of in strict observance of local regulations ATTENTION Store this manual carefully to facilitate future disposal and maintenance work on the equipment KNOWLEDGE OF THE SYSTEM AND PREPARATION FOR INSTALLATION Description and use The Input and Relay Module K30 is an extension for the D PRO Automatic Door Cont...

Page 3: ...n be used to enable or disable the automatic closing function To switch off automatic closing the contact must be opened External OPENING using buttons If traffic lights for two way traffic are connected to the Input and Relay Module K30 a button contact with zero potential closing contact must be connected to terminals I9 and I10 to activate the external green traffic light Partial opening with e...

Page 4: ...lity that the product identified above complies with the provisions of the following directives 2006 42 EC DIRECTIVE OF THE EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 machinery directive The following harmonized standard was applied EN ISO 13849 2008 The safety functions Monitoring of external safety elements contact x6 Cat 2 PLd end position monitoring Cat2 PLd safety circuit emergency stop C...

Page 5: ...I nostri azionamenti e centrali di comando sono omologati dal TÜV NORD XXXXX_17 09 2015 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...

Reviews: