English –
15
English
Example: to adjust the pause time to 40 s.
01.
Press the
T1
and
T2
keys and hold them down for at least 5s
02.
Release
T1
and
T2
03.
Press
T1
three times
All the parameters can be adjusted as required without any contraindica-
tion; only the adjustment of the “motor force” could require special care:
• Do not use high force values to compensate for the fact that the gate
has anomalous friction points. Excessive force can be detrimental to the
functioning of the safety system or can damage the gate.
• If the “Motor force control” is used in support of the system for impact
force reduction, the force measurement procedure must be performed
after each adjustment, as envisaged by standard EN 12445.
• Weather conditions may affect the movement of the gate. Periodically
you may need to readjust.
To program the parameters in Table 4:
01.
Press
T1
and
T3
together (
fig. 32
) on the radio transmitter for at least
5 s.
02.
Release the two keys.
03.
Within three seconds, carry out the action set out in Table 4 based on
the parameter to change.
TABLE 4
Parameters
N° Value
Action to perform
SbS input configuration on the control unit
1
Step-by-Step (*)
Press T1 once
2
pedestrian opening
Press T1 twice
Flash output configuration
1
Flashing light (*)
Press T2 once
2
Courtesy light
Press T2 twice
3
Gate open indicator
Press T2 three times
Motor 1 and Motor 2 discharge in closure
1
No discharge (*)
Press T3 once
2
0.1s (Minimum)
Press T3 twice
3
0.2s
Press T3 three times
4
0.3s
Press T3 four times
5
0.4s (Medium)
Press T3 five times
6
0.5s
Press T3 six times
7
0.6s
Press T3 seven times
8
0.7s (Maximum)
Press T3 eight times
Motor 1 and Motor 2 discharge in opening
1
No discharge (*)
Press T4 once
2
0.1s (Minimum)
Press T4 twice
3
0.2s
Press T4 three times
4
0.3s
Press T4 four times
5
0.4s (Medium)
Press T4 five times
6
0.5s
Press T4 six times
7
0.6s
Press T4 seven times
8
0.7s (Maximum)
Press T4 eight times
(*)
Original factory value
Example: to adjust the closing discharge of motors 1 and 2 to level 4.
01.
Press the
T1
and
T3
keys and hold them down for at least 5s
02.
Release
T1
and
T3
03.
Press
T3
four times
T1
T3
32
TABLE 3
Parameters
N° Valore
Action:
operation to be carried out at step 3 in
the recognition phase
Pause time
1
10s
Press T1 once
2
20s (*)
Press T1 twice
3
40s
Press T1 three times
4
80s
Press T1 four times
Pedestrian opening
1
Open 1 leaf halfway
Press T2 once
2
Fully open 1 leaf (*)
Press T2 twice
3
2 leaves partially opened to 1/4 of the full course
Press T2 three times
4
2 leaves partially opened to half of the full course
Press T2 four times
Motor force
1
Low
Press T3 once
2
Medium low (*)
Press T3 twice
3
Medium high
Press T3 three times
4
High
Press T3 four times
Step-by-Step (SbS) function
1
“Open”, “Stop”, “Close”, “Stop”
Press T4 once
2
“Open”, “Stop”, “Close”, “Open” (*)
Press T4 twice
3
“Open”, “Close”, “Open”, “Close”
Press T4 three times
4
Open only
Press T4 four times
(*)
Original factory value
Summary of Contents for MAESTRO200 Series
Page 2: ......
Page 9: ...Français 7 Français E B A 6 Distance E minimum 400 mm 8 9 M8 V6 x 70 M6 10 11 12 13 7 ...
Page 10: ...8 Français Français OK b c d a Maximum 14 14 15 16 17 18 19 21 20 M8 M8 M8 M8 ...
Page 33: ...English 7 English E B A 6 Distance E minimum 400 mm 8 9 M8 V6 x 70 M6 10 11 12 13 7 ...
Page 34: ...8 English English OK b c d a Maximum 14 14 15 16 17 18 19 21 20 M8 M8 M8 M8 ...
Page 57: ...Italiano 7 Italiano E B A 6 Distanza E minimo 400 mm 8 9 M8 V6 x 70 M6 10 11 12 13 7 ...
Page 58: ...8 Italiano Italiano OK b c d a Massimo 14 14 15 16 17 18 19 21 20 M8 M8 M8 M8 ...
Page 81: ...Polski 7 Polski E B A 6 Odległość E minimum 400 mm 8 9 M8 V6 x 70 M6 10 11 12 13 7 ...
Page 82: ...8 Polski Polski OK b c d a Maksymalny 14 14 15 16 17 18 19 21 20 M8 M8 M8 M8 ...
Page 111: ......