18
– ENGLISH
LEVEL 2 FUNCTIONS (ADJUSTABLE PARAMETERS)
Entry
LED
Parameter
LED
(level)
Set value
Description
L4
Motor
discharge after
closing
L1
No discharge
Adjusts the duration of the “brief reversal” of both
motors, once the closing manoeuvre terminates,
to reduce the residual final thrust.
L2
Level 1 - Minimum discharge (roughly 100 ms)
L3
Level 2 - ...
L4
Level 3 - ...
L5
Level 4 - ...
L6
Level 5 - ...
L7
Level 6 - ...
L8
Level 7 - Maximum discharge (roughly 1 s)
L5
Motor force
L1
Level 1 - Minimum force
Adjusts the force of both motors.
L2
Level 2 - ...
L3
Level 3 - ...
L4
Level 4 - ...
L5
Level 5 - ...
L6
Level 6 - ...
L7
Level 7 - ...
L8
Level 8 - Maximum force
L6
Pedestrian or
partial opening
L1
Pedestrian 1 (the M2 gate leaf opens to 1/4 of
the full range)
Adjusts the type of opening associated with the
“partial opening 1” command.
[
Note :
] “minimum” opening refers to the smallest
opening between M1 and M2; for example, if M1
opens to 90° and M2 opens to 110°, the minimum
opening is 90°.
L2
Pedestrian 2 (the M2 gate leaf opens to 1/2 of
the full range)
L3
Pedestrian 3 (the M2 gate leaf opens to 3/4 of
the full range)
L4
Pedestrian 4 (full opening of gate leaf M2)
L5
Partial 1 (the two gate leaves open to 1/4 of the
“minimum” range)
L6
Partial 2 (the two gate leaves open to 1/2 of the
“minimum” range)
L7
Partial 3 (the two gate leaves open to 3/4 of the
“minimum” range)
L8
Partial 4 (the two gate leaves open to the
“minimum” range)
L7
Maintenance
notice
L1
500
Adjusts the number of manoeuvres after which
the automation maintenance request is triggered
paragraph).
L2
1000
L3
1500
L4
2500
L5
5000
L6
10000
L7
15000
L8
20000
L8
List of
malfunctions
L1
Result of 1st manoeuvre (most recent)
Allows for checking the type of anomaly that
occurred in the last 8 manoeuvres (see the “
” paragraph).
L2
Result of 2nd manoeuvre
L3
Result of 3rd manoeuvre
L4
Result of 4th manoeuvre
L5
Result of 5th manoeuvre
L6
Result of 6th manoeuvre
L7
Result of 7th manoeuvre
L8
Result of 8th manoeuvre