background image

ENGLISH – 

3

 

The manufacturer declines all liability for damages to 

property, objects or people resulting from failure to 

observe the assembly instructions. In such cases, the 

warranty for material defects shall not apply.

 

The weighted sound pressure level of the emission A is 

lower than 70 dB(A).

 

Cleaning and maintenance reserved for the user must 

not be carried out by unsupervised children.

 

Before working on the system (maintenance, cleaning), 

always disconnect the product from the mains power 

supply.

 

Verify the system frequently, in particular check the ca-

bles and supports to detect any imbalances and signs 

of wear or damage. Do not use if repairs or adjustments 

are necessary, because a fault involving the installation 

or an incorrectly balanced automated system may lead 

to injury.

 

The packing materials of the product must be disposed 

of in compliance with local regulations.

 

Keep persons away from the gate when it is manoeu-

vred using the control elements.

 

When operating the gate, keep an eye on the automat-

ed mechanism and keep all bystanders at a safe dis-

tance until the movement has been completed.

 

Do not operate the product if anyone is working near-

by; disconnect its power supply before permitting such 

work to be done.

1.2  INSTALLATION WARNINGS

 

Prior to installing the drive motor, check that all me-

chanical components are in good working order and 

properly balanced, and that the automation can be ma-

noeuvred correctly.

 

If the gate being automated has a pedestrian gate, the 

system must be equipped with a control device that in-

hibits the motor’s operation when the pedestrian gate 

is open.

 

Make sure that the control elements are kept far from 

moving parts but nonetheless directly within sight. Un-

less a selector is used, the control elements must be 

installed at least 1.5 m above the ground and must not 

be accessible.

 

If the opening movement is controlled by a fire-sensing 

system, make sure that any windows larger than 200 

mm are closed using the control elements.

 

Prevent and avoid any form of entrapment between the 

moving and fixed parts during the manoeuvres.

 

Permanently affix the label concerning the manual ma-

noeuvre near its actuating element.

 

After installing the drive motor, make sure that the 

mechanism, protective system and all manual manoeu-

vres function properly.

PRODUCT DESCRIPTION AND 

INTENDED USE

2

 

PRODUCT DESCRIPTION AND INTENDED USE

POP

 is a series of gearmotors with articulated arm and external 

assembly, which can be used to automate residential or indus-

trial swing gates or doors. They are equipped with a sturdy an-

ti-shear aluminium arm and are ideal for intensive use.

The main part of the automation consists of one or more electro-

mechanical gearmotors (depending on the number of leaves to 

be automated), each equipped with a direct-current motor and 

a gear reducer with spur gears.

The 

PP7124

 gearmotor is equipped with a control unit that man-

ages its operation.

The control unit is configured for being connected to the various 

devices belonging to the Opera System, Bluebus system and 

the Solemyo solar power system.

The control unit can also house a back-up battery (model PS124, 

optional accessory) which, in case of a blackout, allows the au-

tomation to carry out certain manoeuvres.In the event of power 

outage, it is still possible to move the gate leaf by unlocking the 

gearmotor with the appropriate key (see the “

Manually unlock-

ing and locking the gearmotor

” paragraph).

The automation allows for installing various accessories to in-

crease its functions and improve safety.

Any use of the product other than the intended use 

described is not allowed!

2.1  LIST OF CONSTITUENT PARTS

Figure

 

1

” shows the main parts making up the 

PP7124

 gear-

motor.

A

E

F

G

H

I

L

D

B
C

1

A

 Cover

B

 Fuse

C

 

Electronic control and command unit (only present on 

PP7124

)

D

 

OXI receiver

E

 

Back-up battery (accessory)

F

 Gearmotor

G

 

Locking/unlocking key

H

 

Gearmotor fixing bracket

I

 

Arm fixing bracket

L

 Arm

Summary of Contents for PP7124

Page 1: ...Nice PP7124 Swing gate opener EN Instructions and warnings for installation and use...

Page 2: ...ion process handle the product with care by avoiding crushing impacts falls or contact with liquids of any kind Do not place the product near sources of heat nor expose it to open flames All these act...

Page 3: ...ontrolled by a fire sensing system make sure that any windows larger than 200 mm are closed using the control elements Prevent and avoid any form of entrapment between the moving and fixed parts durin...

Page 4: ...iquids keep the product away from heat sources and open flames and acid saline or potentially explosive atmospheres these may damage the product and cause malfunctions or danger ous situations if ther...

Page 5: ...t s actual useful life Example of lifetime calculation automation of a gate with a 1 3 m long leaf weighing 180 kg for example with a solid leaf Table 1 shows the severity indices for this type of ins...

Page 6: ...ommended 5 m 4 BLUEBUS DEVICES cable 1 cable 2 x 0 5 mm2 Maximum length 20 m note 2 5 KEY SELECTOR cable 2 cables 2 x 0 5 mm2 note 3 Maximum length 50 m 6 ELECTRIC LOCK cable 1 cable 2 x 1 mm2 Maximum...

Page 7: ...resulting opening angle 3 with the value of distance A and the opening angle found using the graph to determine the distance B For example if A is 100 mm and the desired angle is equal to 100 distanc...

Page 8: ...racket for the gate leaf I to the curved arm F D H F I G G H 15 10 unlock the gearmotor manually see paragraph Manually unlocking and locking the gearmotor 11 decide where to attach the bracket to the...

Page 9: ...mit switch A as shown in the figure 4 loosen the screw that fastens the straight arm to the gear motor 5 apply the protective cover B and re tighten the screw with the washer A B 19 6 move the gate to...

Page 10: ...nection under the Category III overvoltage conditions in accordance with the installation instructions To make the electrical connections 1 open the gearmotor s cover A A 21 2 pass the power cable and...

Page 11: ...Example EPM EDSB ETPB For further information on the BlueBUS refer to the BlueBUS paragraph Stop Input for devices that suspend or even stop the current manoeuvre Normally Closed and Normally Open co...

Page 12: ...EBUS L1 L2 26 The learning process of connected devices can be repeated at any time even after the installation for example whenever a device must be added to complete the new learning process refer t...

Page 13: ...signal the current position STOP SBS OPEN BLUEBUS L1 29 To effect the manual learning procedure 1 simultaneously press and hold the and g buttons h 2 release the buttons when LED L1 starts flashing af...

Page 14: ...on to be programmed 5 proceed for each individual position as described in the Learning in manual mode paragraph 6 repeat this last operation for all the other positions to be modified 5 4 CHECKING TH...

Page 15: ...impact force it is neces sary to test various adjustments to find the one that gives the best results 6 2 COMMISSIONING a Commissioning can only be performed after all test ing phases have been succe...

Page 16: ...ing will not take place if the function is disabled L3 Always Close Function ENABLED in the event of a blackout even of short duration if the control unit detects that the gate is not closed once the...

Page 17: ...omatic Closing is enabled L2 15 seconds L3 30 seconds L4 45 seconds L5 60 seconds L6 80 seconds L7 120 seconds L8 180 seconds L2 Step by Step function L1 Open Stop Close Stop Controls the sequence of...

Page 18: ...d M2 opens to 110 the minimum opening is 90 L2 Pedestrian 2 the M2 gate leaf opens to 1 2 of the full range L3 Pedestrian 3 the M2 gate leaf opens to 3 4 of the full range L4 Pedestrian 4 full opening...

Page 19: ...he limit Lit for 2 seconds at the start of the opening manoeuvre Between 81 and 100 of the limit Flashes for the entire duration of the manoeuvre Exceeding 100 of the limit Flashes always 7 4 3 Verify...

Page 20: ...uring the learning phase There may be defective devices check and replace them if necessary if changes have been made the learning procedure must be repeated 2 flashes 1 second pause 2 flashes Interve...

Page 21: ...r to that shown in Table 8 STOP LED OFF Intervention of the STOP input Check the devices connected to the STOP input On Everything normal STOP input active Sbs LED OFF Everything normal Sbs input not...

Page 22: ...ices can be connected to each other in parallel Any number of NC devices can be connected to each other in series Two devices with 8 2 k fixed resistor output can be connect ed in parallel if there ar...

Page 23: ...commands shown in Table 12 Table 12 OXI IN EXTENDED MODE II No Command Description 1 Step by Step SbS Step by Step command 2 Partial opening 1 Partial opening 1 command 3 Open Open command 4 Close Cl...

Page 24: ...p the spring G by its two ends 6 thread the other end of the cable through the hole located on the lower part of the gearmotor 7 put the cover back on A A C B G D E F 44 8 connect the cable to Kio by...

Page 25: ...B in the appropriate slot C on the control unit s electronic board 3 insert the cable D in the appropriate slot E on the in terface C B D E A 45 4 At this stage the control unit can be powered again l...

Page 26: ...ST NOT BE POWERED by the elec tricity grid at the same time l For information on the Solemyo system consult the relevant instruction manual To connect the Solemyo system 1 remove the cover A 2 remove...

Page 27: ...components replace any worn parts 5 connect the power supplies again and run all the tests and checks described in the Testing paragraph PRODUCT DISPOSAL 11 11 PRODUCT DISPOSAL l This product is an in...

Page 28: ...que 10 minutes Application limits The product can be used on gates with leaves weighing up to 200 kg for lengths up to 2 m Durability Estimated between 80 000 and 250 000 cycles depending on the condi...

Page 29: ...cated fixing plate Operating temperature 20 C 55 C at low temperatures the gearmotor s efficiency decreases Use in highly acid saline or potentially explosive atmosphere No Protection rating IP 44 wit...

Page 30: ...lowing directives according to the requirements envisaged for partly completed machinery Annex II part 1 section B Directive 2006 42 EC of the EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 related to...

Page 31: ...ENGLISH 31 NOTES...

Page 32: ...32 ENGLISH NOTES...

Page 33: ...uipped with back up batteries the automation can none theless be used by manually unlocking the motor consult the instructions at the end of the chapter and moving the gate leaf manually Safety device...

Page 34: ...has come to a standstill To unlock the device 1 raise the small cover 2 insert the key A and turn it clockwise by 90 A 48 3 the gate leaf can now be moved manually to the desired position To lock the...

Page 35: ...ENGLISH 35 NOTES...

Page 36: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IDV0668A00EN_31 01 2019...

Reviews: