28
– ENGLISH
TECHNICAL SPECIFICATIONS
12
12
TECHNICAL SPECIFICATIONS
l
All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). Nice S.p.A.
reserves the right to apply modifications to the product at any time when deemed necessary, without altering
its functions and intended use.
Table 13
TECHNICAL SPECIFICATIONS
Description
Technical specification
PP7124
PP7224
Product type
Electromechanical gearmaotor for
automatic gate and door systems with
direct-current motor, epicyclic gear
reducer and mechanical unlocking
mechanism.
Incorporated control unit and OXI radio
receiver.
Electromechanical gearmaotor for
automatic gate and door systems with
direct-current motor, epicyclic gear
reducer and mechanical unlocking
mechanism.
Peak torque [corresponding to the ability to
develop a force capable of moving the leaf]
250 Nm
Nominal torque [corresponding to the ability
to develop a force capable of keeping the
leaf moving]
100 Nm
Nominal torque speed
0,13 rad/s (1,2 rpm)
No-load speed (the control unit allow for
programming 6 speeds roughly equal to:
100, 85, 70, 55, 45, 30%)
0,17 rad/s (1,6 rpm)
Maximum frequency of operating cycles (at
nominal torque)*
35 cycles/hour
Maximum continuous operating time (at
nominal torque)**
10 minutes
Application limits
The product can be used on gates with leaves weighing up to 200 kg for lengths up
to 2 m.
Durability
Estimated between 80,000 and 250,000 cycles, depending on the conditions
specified in the “
” paragraph.
Power supply POP
230V
a
(120V
a
for version PP7124/V1)
(±10%) 50/60 Hz
24V
c
(±25%)
Emergency power supply
With optional accessory PS124
-
Solar panel power supply
Configuration for SYKCE kit
-
Maximum power draw at nominal torque
170W
50W
Peak power
280W
100W
Nominal current draw
0,8 A (1,6 A for version PP7124/V1)
2 A
Maximum current draw
1,3 A (2,6 A for version PP7124/V1)
4 A (for maximum 1 s)
Power draw in “Stand-by-All” mode with
power supply from PS124 or SYKCE kit
(including OXI receiver)
Below 100 mW
-
Warning light output***
One ELB (lamp 12 V
c
, 21 W) or ELDC
warning light
-
Electric lock output***
One 12 V
a
max 15 VA electric lock
-
BLUEBUS output
One output with maximum load of 12
Bluebus units
(maximum 6 pairs of EPM photocells plus
2 pairs of EPM photocells addressed as
opening devices plus maximum 4 EDSB
or ETPB control devices)
-
STOP input
For normally closed or normally open
contacts or for 8.2 kΩ fixed resistor
contacts with self-learning (any variation
from the memorised status triggers the
STOP command)
-
Sbs input
For normally open contacts (closing of
the contact triggers the STEP-BY-STEP
command)
-
OPEN input
For normally open contacts (closing of
the contact triggers the PARTIAL OPEN 1
command)
-