24
Use in particularly acidic, saline or potentially
explosive atmospheres
400 x 255 h 390; 24.5Kg
With the aim of improving products, Nice S.p.a reserves the right to modify technical characteristics at any time without notice, while main-
taining the same functionalities and intended use.
All technical characteristics stated refer to an ambient temperature of 20°C (±5°C).
8) Technical characteristics
Type
Model type
RUN Technical characteristics
Electromechanical gearmotor for automatic movement of sliding gates for industrial use
complete with electronic control unit.
RUN 1800 - RUN 1800P
RUN 2500 - RUN 2500P
Pinion
Number of teeth 18; Module 4 *
Maximum torque on start-up
[corresponds to ability of generating the
force required to move the leaf]
50Nm
(1390N)
Nominal torque
[corresponds to the ability of generating the
force to maintain the leaf in movement]
32,5Nm
(900N)
Speed (no-load)
10m/min (12m/min version /V1)
Speed (at nominal torque)
8,5m/min (8.9m/min version /V1)
Maximum frequency of operating cycles (at
nominal torque)
11 cycles/hour (264 cycles/day),
for a gate of 15m (equal to a cycle of 63%),
(the control unit limits cycles to the maxi-
mum number specified in tables 2 and 3)**
Maximum time of continuous operation (at
nominal torque)
40 minutes (the control unit limits
continuous operation to the maximum
limits as specified in tables 2 and 3)***
Operating limits
In general RUN is designed for the automa-
tion of gates with the weights and lengths as
specified in tables 2, 3 and 4
Durability
Estimated between 150.000 cycles and 450.000 cycles according to conditions specified in
table 4
Maximum power absorption on start-up
[corresponding to Amps]
700 W [3 A] [5 A version /V1]
Power at nominal torque
[corresponding to Amps]
400 W [1.8 A] [3 A version /V1]
Insulation class
1 (safety earthing required)
Flashing light output
For 2 Flashing lights LUCYB (lamp 12V, 21W)
BLUEBUS output
One output with maximum load of 15 BlueBus units
Gate open indicator output
For 1 24V lamp of maximum 4W (output voltage may vary between -30 and +50% and
can also control small relays)
STOP input
For normally closed contacts , normally open contacts or with constant 8,2K
Ω
. resistance; in self-
learning (a variation with respect to memorised value generates the STOP command)
Step-by-step input
For normally open contacts (contact closure generates S.S. command)
OPEN input
CLOSE input
For normally open contacts (contact closure generates OPEN command)
For normally open contacts (contact closure generates CLOSE command)
Radio connector
SM connector for receivers SMXI; SMXIS or ONEXI
Radio ANTENNA input
Input ANTENNA Radio 52
Ω
for cable type RG58 or similar
Power supply RUN 1800 - 2500
230Vac (+10% -15%) 50 Hz
Power supply RUN 1800/V1-2500/V1
120Vac (+10% -15%) 60 Hz
Programmable functions
8 ON-OFF type functions and 8 settable functions (see tables 7 and 9)
Operating temperature
-20°C ÷ 50°C
No
Protection rating
IP 44
Dimensions and weight
* Optional 12-tooth 6 module pinion available
** At 50°C and with a gate of 15 metres, the maximum operating frequency is 7 cycles/hour (equal to a cycle of 40%).
*** At 50°C the maximum continuous operation time is 10 minutes.
Functions in self-learning mode
Self-learning of devices connected to BlueBus output.
Self-learning of "STOP" device type (contact NO, NC or 8,2K
Ω
resistance) Self-learning of
gate length and calculation of deceleration and partial opening points.