EN
English –
15
PRODUCT DISPOSAL
This product is an integral part of the automation system it controls and
must be disposed of along with it.
As in the case of installation, likewise at the end of product lifetime the disas-
sembly and scrapping operations must be performed by qualified personnel.
This product is made of various types of material, some of which can be recy-
cled while others must be scrapped. Seek information on the recycling and dis-
posal methods envisaged by the local regulations in your area for this product
category.
Caution!
– Some parts of the product may contain polluting or hazardous sub-
stances which, if released to the environment, may cause serious damage to
the environment or to human health.
As indicated by the symbol alongside, disposal of this prod-
uct with domestic waste is strictly prohibited. Separate the
waste into categories for disposal, according to the methods
established by current legislation in your area, or return the
product to the retailer when purchasing a new version.
Caution!
– Local legislation may impose heavy fines in the event of illegal dis-
posal of this product.
TECHNICAL CHARACTERISTICS OF THE PRODUCT
WARNINGS: •
All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to apply modifi-
cations to products at any time when deemed necessary, maintaining the same intended use and functionality.
Product Type
SBAR is an electromechanical road barrier for residential use. Controls opening and closing of
an access point with a maximum width of 4 m. Complete with electronic control unit
Maximum torque on start-up
100 Nm
Nominal torque
25 Nm
Maximum operating
cycle frequency
100 (80 with XBA4 accesory) cycles / hour
at nominal torque
*
Maximum continuous operating
10 (8 with XBA4 accesory) minutes
time at nominal torque
**
Opening time
≥
4 s (>5s with XBA4 accesory)
Durability
between 80,000 and 500,000 manoeuvre cycles according to the conditions stated in Table 2
Peak power supply
230 Vac (50/60Hz)
Peak power absorption on start-up
300W
Maximum power at nominal torque
200 W
Insulation class
I
Emergency power supply
Yes (with PS124 accessory)
Courtesy light
With XBA7 LED flashing accessory
Flashing light output
For 1 flashing light LUCYB, MLB or MLBT (12 V - 21 W lamp)
BLUEBUS output
1 output with maximum load of 12 Bluebus units
STOP Input
For normally closed, normally open or 8.2 k
Ω
; constant resistance contacts in self-learning mode
(a change from the memorised state prompts the "STOP" command)
S.S. input
For normally open contacts (closure of the contact prompts the Step by Step command)
OPEN Input
For normally open contacts (closure of the contact prompts the OPEN command)
CLOSE Input
For normally open contacts (closure of the contact prompts the CLOSE command)
Radio AERIAL input
52
Ω
for RG58 or similar type cable
Radio connector
SM connector for receiver types SMXI, SMXIS or OXI, OXIT and OXIFM
Programmable functions
8 ON-OFF type functions and 8 adjustable functions (see tables 6 and 7)
Self-learning of devices connected to the BlueBus output. Self-learning of "STOP"
Functions in self-learning mode
type devices (contacts NO, NC or 8,2K
Ω
). resistance). Learning of pole opening and closing positions and
calculation of the points of deceleration and partial opening
Operating temperature
from -20° C to +50° C
Use in particularly acid,
saline or potentially
No
explosive atmospheres
Protection rating
IP 44
Dimensions
1146 x 330 h 179,5;
pole
: minimum 2 m - maximum 4 m
Weight
35 Kg
Note
:
(
*
) At 50°C the maximum operating frequency is 40 cycles/hour
(
**
) At 50°C the maximum continuous operating time is 5 minutes.
Summary of Contents for S-BAR
Page 78: ...I 2 1 A B C B 179 5 mm 330 mm 1146 mm 826 mm 4000 mm 3 b a d e f g h c ...
Page 79: ...II 5 A B C 1 2 4 ...
Page 80: ...III 9 10 90 6 A C B 7 8 B A ...
Page 81: ...IV 14 15 A B A B 11 A B 12 13 A B ...
Page 82: ...V 16 A B 17 18 ...
Page 83: ...VI 20 180 21 C C A B 1cm 1cm 19 A C B ...
Page 84: ...VII 22 23 26 L N 24 1 2 25 ...
Page 86: ...IX 30 A A B STOP 31 A B ...
Page 87: ...X 32 A B C D STOP 33 A B 34 ...
Page 88: ...XI 35 36 L8 37 A B 2 1 L7 L8 L8 A B C Op L5 L6 L7 L8 Stop Set Close F u s e 1 A T 38 ...
Page 89: ...XII 300 200 700 500 39 300 200 700 500 150 40 41 ...
Page 90: ...a c d e b XIII F2 F1 42 43 ...
Page 91: ...XIV 44 O pe n L1 L2 L3 L4 L5 L6 L7 L8 St op Se t Cl os e Fuse 1AT 45 f g ...
Page 93: ...IST SBARR01 4865_20 10 2011 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...