background image

EN

English – 

1

Contents

PICTURES

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  I - XII

Chapter 1 - WARNINGS AND GENERAL PRECAUTIONS

1 .1 - Safety instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  1

1 .2 - Installation warnings   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  1

1 .3 - Special warnings related to European Directives applicable 

to the product    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .1

  1 .3 .1 - Installation criteria and special warnings related to essential 

requirements    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

Chapter 2 - PRODUCT DESCRIPTION AND INTENDED USE

   .  .  .  .  .  .  .  .  3

Chapter 3 - INSTALLATION

3 .1 - Preliminary checks for installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

3 .2 - Product application limit   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

  3 .2 .1 - Product durability  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

3 .3 - Typical system   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

3.4 - Barrier fixture   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

  3.4.1 - If the support surface already exists   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

  3.4.2 - If the support surface does not exist    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

3 .5 - Pole installation    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

  3 .5 .1 - Pole support assembly  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

  3 .5 .2 - Pole assembly   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

3 .6 - Manually releasing and locking the gearmotor    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

3 .7 - Mechanical stop adjustment  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

3 .8 - Pole balancing   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

Chapter 4 - ELECTRICAL CONNECTIONS

4 .1 - Description of the electrical connections  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5

4 .2 - Initial start-up and connection check    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5

4 .3 - Pre-set functions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5

4 .4 - Recognition of the connected devices   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5

4 .5 - Recognition of limit positions on opening and closing  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5

4 .6 - Pole movement check   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

4 .7 - Connecting a radio receiver   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

4 .8 - Connecting the pole lights (optional accessory)    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

4 .9 - Connection of other devices    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

  4 .9 .1 - Programming unit Oview   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

  4 .9 .2 - Buffer battery mod . PS124 (accessory)    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

  4 .9 .3 - Solemyo System (photovoltaic supply)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

Chapter 5 - TESTING AND COMMISSIONING

5 .1 - Testing  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

5 .2 - Commissioning    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  7

Chapter 6 - CONTROL UNIT PROGRAMMING

6 .1 - Level one programming (ON-OFF functions)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  7

6 .2 - Level two programming (adjustable parameters)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  8

  6.2.1 - Examples of programming: levels 1 and 2   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  10

Chapter 7 - TROUBLESHOOTING... (troubleshooting guide)

   .  .  .  .  .  .  .  .10

Chapter 8 - FURTHER INFORMATION

8 .1 - Total deletion of control unit memory   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  11

8 .2 - Other functions    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  11

8 .3 - Adding or removing devices   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  12

  8 .3 .1 - Bluebus Input  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  12

  8 .3 .2 - Photocells   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  12

  8.3.3 - MOTB digital selector and proximity reader for MOMB 

transponder cards    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  13

  8 .3 .4 - STOP Input    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  13

8 .4 - Diagnostics    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  13

  8 .4 .1 - Signals of control unit  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  13

  8 .4 .2 - Flashing light signals    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  14

PRODUCT DISPOSAL

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  15

TECHNICAL CHARACTERISTICS OF THE PRODUCT

   .  .  .  .  .  .  .  .  .  .  .  .  .  15

Declaration of Conformity appendix I

 (removable appendix)   .  .  .  .  .  .  .  .  .  16

Operation manual 

(removable appendix)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  17

Maintenance schedule 

(removable appendix)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  19

CE DECLARATION OF CONFORMITY and declaration of incorporation 

of “quasi machine”

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  21

ENGLISH

1.1 - Safety instructions

• CAUTION! – This manual contains important instructions and warn-

ings for personal safety.

 Incorrect installation could cause serious physi-

cal injury . We recommend that you read this entire manual with care before 

starting any work . If in doubt, do not install the product and contact the Nice 

technical assistance department .

• CAUTION! – Important instructions: keep this manual in a safe place 

to enable future product maintenance and disposal operations.

1.2 - Installation warnings

• Before commencing installation, check that the product is suitable for the 

intended kind of use (see paragraph 3 .1 and 3 .2) .If not suitable, do NOT 

proceed with installation .

• The contents of this manual refer to a standard system such as that shown in 

fig. 1

 .

  Considering the risk situations that may arise during installation phases and 

use of the product, the automation must be installed in observance of the 

following warnings .

  - On the power line to the system, install a device for disconnection from the 

power mains with a gap between contacts that assures complete disconnec-

tion in the conditions of overvoltage category III .

  - All product installation and maintenance operations must be performed with 

the automation disconnected from the power mains . If the power disconnect 

device is not visible from the location of the automation, before starting work-

ing, a suitable notice must be affixed on the power disconnect device stating 

“WARNING! MAINTENANCE IN PROGRESS” .

  - Connect the product to an electric power line equipped with an earthing 

system .

  - During installation, handle the automation with care to avoid crushing, impact, 

dropping or contact with liquids of any type . Never place the product near 

sources of heat or expose to naked flames. This may damage product com-

ponents and cause malfunctions, fire or hazardous situations. If this occurs, 

suspend installation immediately and contact the Nice Service Centre .

  - Never make modifications to any part of the product. Operations other than 

as specified can only cause malfunctions. The manufacturer declines all liabil-

ity for damage caused by makeshift modifications to the product.

  - This product is not designed to be used by persons (including children) 

whose physical, sensorial or mental capacities are reduced, or with lack of 

experience or skill, unless suitable instructions regarding use of the product 

have been provided by a person responsible for safety .

  - The product may not be considered an efficient system of protection against 

intrusion. If an efficient protection system is required, the automation must be 

integrated with other safety devices .

  - Do not allow children to play with fixed control devices. Keep remote control 

devices out of reach of children .

  - X-Bar cannot be used before the commissioning procedure as specified in 

chapter 5 “Testing and commissioning” .

  - The product’s packaging materials must be disposed of in full compliance 

with local regulations .

1.3 -  Special warnings related to European Directives applica-

ble to the product

• “Construction Products” Directive:

  Special warnings related to 89/106/EEC “Construction Products” Directive 

and subsequent modification 98/38/EEC applicable to the product:

  - Complete installation of this product, as described in this instruction manual 

and for certain types of use (for example excluding exclusive use for vehicles) 

may class it in the field of application of the Directive “Construction Products” 

89/106/EEC and relative harmonised standard EN 13241-1 .

  - Paragraph 1.3.1 specifies all installation criteria required to ensure that the 

pro duct complies with the essential requirements of the directive 89/106/

EEC; the installer should check and ensure that all these criteria are strictly 

observed .

  - Failure to observe one or more of these criteria may mean that the X-Bar 

product may not meet all the essential requirements . 

Use of the product 

in these situations is strictly prohibited until all the directive require-

ments are met; in this case, the label “ES13241-1.4870” applied on 

the product must be removed and the “EC declaration of Conform-

ity” in appendix I of this manual may not be used.

 As a consequence, 

the installer in turn becomes the manufacturer of the “automatic barrier”, 

and must therefore ob serve all requirements of the Directive “Construction 

Products” 89/106/EEC and relative harmonised standard EN 13241-1 . In this 

case X-Bar must be considered as a “machine component” and the “Decla-

ration of conformity” in appendix II may be used (for insertion in the technical 

documentation) .

• “Machinery Directive”:

  - Paragraph 1.3.1 specifies all installation criteria required to ensure that the 

product complies with the essential requirements of the “Machinery directive” 

2006/42/EC (ex 98/37/EC). The installer should check and ensure that all 

these criteria are strictly observed .

  - Failure to observe one or more of these criteria during installation or use 

WARNINGS AND GENERAL PRECAUTIONS

1

Summary of Contents for X-Bar

Page 1: ...ione e l uso FR Instructions et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalaci n y el uso DE Installierungs und Gebrauchsanleitungen und Hinweise...

Page 2: ......

Page 3: ...I 1 A B D C D B 3 2 179 5 mm 300 mm 1146 mm 826 mm 3000 mm b a l d e c i g f h...

Page 4: ...II 5 A B C 4...

Page 5: ...III 9 10 90 6 A C B 7 8 B A...

Page 6: ...IV 14 A B 15 A B 11 A B 12 13 A B...

Page 7: ...V 18 17 16 A B...

Page 8: ...VI 20 21 OK O O 19 A B C D...

Page 9: ...VII 22 A 2cm 1cm 23 A B C D...

Page 10: ...VIII 24 26 27 180 25 C C A B...

Page 11: ...L N 28 29 NC NC NO NO C C FLASH MOTB OPEN CLOSE TX RX BLUEBUS STOP OPEN CLOSE P P 31 Op en Sto p Se t Clo se Fuse 1AT L1 L2 L3 L4 L5 L6 L7 L8 32 Op en Sto p Se t Clo se Fuse 1AT L1 L2 L3 L4 L5 L6 L7...

Page 12: ...X Op en St op Se t Cl os e Fuse 1AT L1 L2 L3 L4 L5 L6 L7 L8 34 35 36 A A B...

Page 13: ...XI STOP 37 A B 38 A B C D...

Page 14: ...XII 51 O p e n L 1 L 2 L 3 L 4 L 5 L 6 L 7 L 8 S t o p S e t C lo s e Fuse 1AT Open Stop Set Close 49 F2 F1 50 48 O pe n L1 L2 L3 L4 L5 L6 L7 L8 St op Se t Cl os e Fuse 1AT 52...

Page 15: ...ation disconnected from the power mains If the power disconnect device is not visible from the location of the automation before starting work ing a suitable notice must be affixed on the power discon...

Page 16: ...es The product does not contain and or release hazardous substances in con formity with the provisions of the standard EN 13241 1 point 4 2 9 and ac cording to the list of substances stated in the web...

Page 17: ...talled is in a sheltered location and pro tected against the risk of accidental impact 3 2 Product application limit Before installing the product ensure that all values specified in the chapter Techn...

Page 18: ...ll parts 09 Position the pole plug Fig 23 A the upper impact protection must be inserted by at least 2 cm the lower impact protection must protrude by 1 cm B Insert the pole plug C Secure the plug usi...

Page 19: ...chanical stop is moved IMPORTANT The deceleration points are calculated automatically by the control unit after the position search phase at least 2 or 3 complete manoeu vres must be performed before...

Page 20: ...t Fig 44 04 Disconnect the mains power and fit the connector as shown in Fig 45 4 9 3 Solemyo System photovoltaic supply X Bar is designed to be powered with the Solemyo SYKCE photovoltaic system To c...

Page 21: ...the device engages changing from the active status to alarm status and vice versa and that the envisaged action is gen erated in the control unit for example movement inversion in the Closing manoeuv...

Page 22: ...tion both in Opening and Closing If the function is deactivated deceleration is short L6 Pre flash This function activates a pause of 3 seconds between activation of the flashing light and the start o...

Reviews: