Select the primary base unit (Only kg/lb version)
F01
0
primary unit is kg
1
primary unit is lb
Serial port usage
F02
0
Not Usage
1
Connection to serial Printer
Automatic Zero tracking
F03
0
None Automatic zero
1
~
9
0.5 digit
.
.
4.5 digit
Auto zero tracking will automatically bring
the display back to "0" when there are
small deviations.
Digital Filter
F04
0
None Digital filter
Adjust the set value according to the
condition.
1
~
9
1 : Less Vibration
.
.
9 : Much Vibration
Select the weight back-up mode
F07
0
Weight back-up is off (Power on Zero)
1
Weight back-up is on
"PRINT" Key Usage (Only kg/lb version)
F08
0
Not used
1
- Print key
- Total Print key (by pressing "PRINT" key more than 3 second)
2
HOLD Key