Pallet Scale
11. Error message & Troubleshooting
Err 01
Reason
▣
The weight is too unstable to initialize the scale.
Troubleshooting
☞
Lay the scale on a plat place and turn on the power.
Err 02
Reason
▣
Load cell connection failure or error in A/D conversion part.
Troubleshooting
☞
Check the load cell connector to see if the polarity of signal is reversed.
Err 06
Reason
▣
Error in printer connection
Troubleshooting
☞
Check with printer connector
If there is no problem with printer and printer connector, please request
A/S to head office.
Err 08
Reason
▣
The ZERO key or TARE key is adjusted not to be operated under the
unstable condition.
Troubleshooting
☞
Press Zero or Tare key in stable condition
Err 09
Reason
▣
Current weight deviates from zero range.
Troubleshooting
☞
Press the ZERO key within 10% of the maximum capacity.