background image

7

Key to Model Codes (CAPX ab - cd - e):

Product family

Material

Number of

Capacity in kg Dimensions

Resolution

........

load cells

see Table 2

see Table 1

see Table 2

CAPX..

a

b

c

d

e

Combics

S = stainless steel

1 = one load cell

Analog

4 = four load cells

3

Platform

6

........

15

........

30

........

60

........

150

........

300

........

600

........

1500

........

3000

Table 1: Model-specific data: Dimensions
Designation

DC

ED

FE

GF

IG

LL

NL

RN

RR

WR

Width (mm)

240

300

400

500

600

1000

1000

1250

1500

1500

Length (mm)

320

400

500

650

800

1000

1250

1500

1500

2000

Cable lengths (power cord)

Length (m), approx.

1.5

1.5

3.0

3.0

3.0

6.0

6.0

6.0

6.0

6.0

Table 2: Resolutions:
1 weighing range

2 weighing ranges*

 -L

-I  

-LCE

_____

-NCE 2 

3000e

  _____

Weighing

  

_____

Weighing

Weighing

Resolution

Weighing _____ Resolution

range

15,000d

30,000d

1 x 3000e

_____

range

range 1 _____ Range 1

range 2

Range 2

in kg

in g

in g

in g

in kg

in kg

in g

in kg

in g

3 ......

0.2

0.1

1

3

1.5

0.5

3

1

6 ......

0.5

0.2

2

6

3

1

6

2

15 ....

1

0.5

5

15

6

2

15

5

30 ....

2

1

10

30

15

5

30

10

60 ....

5

2

20

60

30

10

60

20

150 ..

10

5

50

150

60

20

150

50

300 ..

20

10

100

300

150

50

300

100

600 ..

50

20

200

600

300

100

600

200

1500

100

50

500

1500

600

200

1500

500

3000

200

100

1000

3000

1500

500

3000

1000

* The weighing ranges allowed in legal metrology in the EU are listed in the Declaration of Conformity.  On weighing instruments with

two weighing ranges (2 x 3000e), the instrument does not automatically switch back to the higher resolution of the fine range once
you use the second, higher-capacity range.  In other words, the lower resolution of the higher range is retained.

Example: CAPXS4-3000WR-NCE  = Combics analog platform in stainless steel with 4 load cells, weighing capacity 3000 kg, 2 x 3000e

in verifiable version.

Summary of Contents for Sartorius Combics CAPXS Series

Page 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Page 2: ...98648 010 95 Operating Instructions Sartorius Combics CAPXS Models Stainless Steel Weighing Platforms for Use in Hazardous Areas Locations...

Page 3: ...ve the following warning and safety information in its entirety during installation and operation as well as while performing maintenance and repair work on the equipment It is important that all pers...

Page 4: ...Always make sure the weighing platform is disconnected from AC power before performing any installation cleaning maintenance or repair work If the equipment housing is opened by anyone other than per...

Page 5: ...ockwise To lower the weighing platform retract the leveling feet turn counterclockwise After leveling the weighing platform retighten the lock nuts securely as described below Low capacity platforms 1...

Page 6: ...with a 3 m cable for connecting the indicator See also the Certificate of Proof of Intrinsic Safety in the appendix to this manual The explosion protected weighing system must be installed in accordan...

Page 7: ...n of the cable end Expose enough of the wires in the cable for installation Remove the casing from approx 1 cm 0 5 in of the wires and affix ferrules to the wire ends Slide the enclosed protective sle...

Page 8: ...0 000d 1 x 3000e _____ range range 1 _____ Range 1 range 2 Range 2 in kg in g in g in g in kg in kg in g in kg in g 3 0 2 0 1 1 3 1 5 0 5 3 1 6 0 5 0 2 2 6 3 1 6 2 15 1 0 5 5 15 6 2 15 5 30 2 1 10 30...

Page 9: ...of the load center side one sided corner load the maximum capacity of the weighing platform is as follows Model Center Side Corner DC 50 35 20 ED 130 85 45 FE 300 200 100 GF 450 300 150 IG 900 600 30...

Page 10: ...of the inside of the scale or flush out using a gentle stream of water 60 C max Make sure that no debris builds up in the gap between the load receptor and the fastening plate to avoid compromising th...

Page 11: ...ndustrial areas continuously monitored operation Limitation of emmissions Residential areas Class B Important Note The operator shall be responsible for any modifications to Sartorius equipment and fo...

Page 12: ...EG01CWS 1000 x1000 1000 YEG02CWS 1250 x 1000 1000 YEG03CWS 1500 x 1250 1250 YEG04CWS 1500 x 1500 1500 YEG05CWS 2000 x 1500 1500 YEG06CWS Roller conveyor stainless steel for platform sizes Size in mm A...

Page 13: ...12 EC Type Approval Certificate...

Page 14: ...13...

Page 15: ...14...

Page 16: ...15...

Page 17: ...15...

Page 18: ...16...

Page 19: ...17...

Page 20: ...18...

Page 21: ...19...

Page 22: ...20...

Page 23: ...21...

Page 24: ...22...

Page 25: ...23...

Page 26: ...24...

Page 27: ...25...

Page 28: ...26...

Page 29: ...27...

Page 30: ...28...

Page 31: ...29...

Page 32: ...30...

Page 33: ...31...

Page 34: ...eans without the prior written permission of Sartorius AG The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius AG reserves the r...

Reviews: