Holding Register 36: Maximum Power [W]
This register can be set to reduce the power out to the motor.
Allowed values = [10, Default Value]
Default value = table below
Value
1.05kW
1-Phase
1050
2.1kW
1-Phase
2100
2.65kW
3-Phase
2650
5.5kW
3-Phase
3900-5600
*
Holding Register 45: Modbus Address [Adim]
This register can be used to change the Modbus address of a driver.
Allowed values = [1, 247]
Default value = 1
Holding Register 46: Tachometric / Alarm / Threshold [Adim]
This register can be used to set the digital output function.
Allowed values = table below
Default value = 0
17.3.11 Holding Register 35
Holding Register 35: Stop Speed
This register can be used to set the stop speed.
When the fan speed is set to 0 rpm if the 0<Stop Speed<Max Speed, the fan decelerates gradually until the
Stop Speed value is reached and then the fan is let in free run.
Allowed values = [0, 20000]
Default value = 20000
17.3.12 Holding Register 36
*
The value depends on the type of impeller installed (355: 5600; 400: 5600; 450: 5600; 500: 5500; 560:
4700; 630: 3900)
17.3.13 Holding Register 45
17.3.14 Holding Register 46
The possible settings are:
0
Tachometric
The digital output indicates the measured speed through a PWM signal
1
Alarm
The digital output indicates when an alarm occurs
2
Threshold
The digital output indicates when the speed set in the Holding Register 55 is
overtaken
3
Out of Functioning
Range
The digital output indicates when the fan is working in a defined range of
speeds