54
5. Settings
Digitax SF I
nstruction Man
ual
5. Parameters
No. 113.0
Tuning:
Position control mode - Control gain set
Range
Default
Characteristics
5 to 45
15
Function
Use
Select one control gain set for Position Control Mode.
Control Gain 1
(115.0),
Control Gain 2
(116.0), and
Integral Gain
(119.0) are set to the preset
values of pairs.
Noise Solutions
① Use
Torque command filter: Notch filter
(such as 160.1).
② Decrease the value of
Integral Gain
(119.0).
③ Decrease the value of
Control Gain 2
(116.0).
If the above does not work, lower
the
Control Gain Set.
Setting
Command Response Rigidity
Settling Time
Possibility of Noise
5
slower
lower
longer
lower
↑
↑
↑
↑
↑
↓
↓
↓
↓
↓
45
faster
higher
shorter
higher
Prerequisite
Position Control Mode
Remark
・Too large a value
in this parameter
may cause noise.
・The default value varies depending on the setting of
Position Control Mode - Inertia conditions
(113.1).
・If
Torque command filter: Low-pass filter - Auto setting
(160.2) = 1 (auto setting ON), then
Torque
command filter: Low-pass filter - Time constant
(162.0) will be included in the gain set.
Related To
No. 113.1, No. 114.0, No. 115.0, No. 116.0, No. 117.0, No. 118.0, No. 119.0, No. 162.0
7
Tuning
-
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...