No. 113.1
Tuning:
Position control mode - Inertia conditions
Settings
Default
Characteristics
0 to 3
2
Function
Use
Set the inertia conditions for Position Control Mode.
This parameter is used to determine the ratio of
Control Gain 1
(115.0) to
Control Gain 2
(116.0),
which would be appropriate to equipment characteristics.
Settings
Description
1
Heavy-load equipment or equipment with substantial load fluctuation
Equipment with low rigidity, robot arms, and so on
2
(medium setting)
For example, general transport machines
3
Light-load equipment
Equipment that demands high-speed operation or requires settling
Prerequisite
Position Control Mode
Related To
No. 113.0, No. 115.0, No. 116.0