94
5. Settings
Digitax SF I
nstruction Man
ual
5. Parameters
No. 648.0
Homing:
Rapid speed
Range
Default
Characteristics
1 to Motor max rotational speed
500
[
rpm]
Function
Use
Specify the speed value for rough approach motion before the home reference
signal is detected.
Time
Homing:
Rapid speed (No.648.0)
Speed
Homing:
Creep speed(No.649.0)
Homing:
Acceleration/Deceleration time(No.650.0)
OFF
ON
OFF
ON
OFF
ON
Homing Start Signal
Home Reference Signal1
Home Reference Signal 2
No. 649.0
Homing:
Creep speed
Range
Default
Characteristics
1 to Motor max rotational speed
10
[
rpm
]
Function
Use
Specify the speed for careful approach after the home signal is detected.
To improve accuracy to detect the home reference signal, select a lower speed.
Prerequisite
Homing: Creep speed switch(647.1):1(Move)
Related To
No. 645.0, No. 647.1, No. 648.0
No. 650.0
Homing:
Acceleration/Deceleration time
Range
Default
Characteristics
0 to 5,000
30
[
ms
]
Function
Use
Set Acceleration/Deceleration Time for homing.
This item indicates time amount for a speed to change 1,000
rpm
.
Applies to
Rapid Speed
(648.0) and
Creep Speed
(649.0)
Remark
If the load is more than 10 times of inertia ratio, set this parameter to a value larger than the default.
Otherwise, vibration may occur.
No. 651.0
Homing:
Amount of home position shift
Range
Default
Characteristics
0 to 1,000,000,000
0
[command pulse]
Function
Use
Use this parameter to set shift amount from home signal or encoder Z-phase to home.
Related To
No. 646.0
-
-
-
-
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...