10
Digitax SF
Instruction Manual
6. Operation
3. Velocity Control Mode
3. Velocity Control Mode
1. Analog Velocity Command
Required Parameters
Optional Parameters
Parameter No.
Name
Setting
2.0
Control Mode
1
: Velocity Control mode (Default: 0 P
o
sition control mode)
3.0
Command Mode
2
: Analog command (Default: 1 Pulse train command)
Name
Explanation
Parameter No.
Offset
Adjustment
Adjust the offset, such that the motor
speed becomes 0
rpm
when the command
input is 0 V.
62.2
Value
60.0
Direction of Rotation
Select CCW or CW.
(*3)
62.0
Input Filter
Enable
Switch
Apply this parameter to filter the noise
component of input command voltage.
62.1
Numerator
48.0
Denominator
49.0
Input gain
Numerator
Set the rotational speed at max command
input voltage (±10 V).
(*1)
50.0
Denominator
51.0
Speed limit
CCW
Numerator
Set the speed limit for CCW rotations.
(*2)
52.0
Denominator
53.0
CW
Numerator
Set the speed limit for CW rotations.
(*2)
54.0
Denominator
55.0
Smoothing
Filter
Enable
Switch
Apply this filter to reduce the variance of
the motor speed.
77.0
Moving Average Time
78.0
The following parameters are optional. Configure them as necessary.
Start testing only after configuring the parameters.
Set the opera
t
ing
mode.
5
Settings
Summary of Contents for Control Techniques Digitax-SF DA21223
Page 6: ...6 MEMO Digitax SF Instruction Manual ...
Page 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Page 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Page 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Page 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Page 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...