19
8
Troubleshooting
8. Troubleshooting
Digitax SF
Instruction Man
ual
4. Troubleshooting
4. Troubleshooting
Problem 2(
No current flows to the motor
)
Cause
Remedy
The servo on signal (SVON) is not
being input.
Input the SVON signal of the host connector to the user I/O connector.
The
AC Supply
is not
present
.
(Alarm No.15 is displayed)
Verify that CHARGE LED is on.
If it is off, verify that the
AC
supply connections are
not loose, and the
voltage is present.
The motor power connector is
loose.
Connect the
Motor Power
connector firmly.
The
drive
has failed
.
Please contact
the supplier of the drive
.
The Setup Panel shows, but the servo cannot be
enabled
.