30
ON
ON
ON
OFF
OFF
2 ms(typ.)
ON
OFF
30
rpm
0
rpm
T1
(*2)
OFF
20 ms(typ.)
ON
25 ms(min.)
20 ms(typ.)
ON
150 ms(typ.)
150 ms(typ.)
(*1)
OFF
T1
(*2)
ON
t
ERROR
NO ERROR
OFF
( = ALARM )
ON
( = NO ALARM )
IN
OUT
Internal
IN
OUT
Internal
Internal
OUT
OUT
IN
3. Preparation
Digitax SF
Instruction Manual
3. Timing Diagrams
Alarm Reset (Servo ON)
*1)
Motor Excitation Status
remains OFF until motor rotational speed drops to 30 rpm or below.
*2) T1 is specified by B
r
ake release Delay time (No.238.0).
Signal Description
Name
Timing Diagrams
(Output Transistor Status, I/O Input Status, and Internal Status)
AC Supply
Power
L1L2
or
L1L2L3
Servo Ready
SRDY
Servo On
SVON
Reset
RESET
Internal Error Status
-
Motor Excitation Status
-
Deceleration Stop Status
-
Servo Status
SERVO
Motor
Brake Release
MBRK
Alarm Status
ALM
Motor Rotational Speed
-
3
Preparation
3.
Timing Diagrams
Summary of Contents for Control Techniques Digitax-SF DA21223