9
STEP 8: The Motor Is Ready for Operation!
The RESCUE
®
is pre-programmed with default settings.
The motor is ready to perform.
(Optional) You can customize the motor, if you want to.
Interested in Advance Configuration and Programming?
Download the App
! Refer to the download and programing instructions beginning on
page 11.
Advance
features allow you to:
Access direct OEM Profiles.
Create a Customized Profile.
Make airflow setting adjustments on-the-fly.
Program other advanced capabilities.
Motor Start-Up and Operation
For default settings, the first time the RESCUE
®
Select Pro is powered on and receives a run signal from
the system control board, it performs a rotation sensing process. The motor runs for approximately 20
seconds in each direction to determine the proper direction for the application. Once the motor determines
the proper operating direction, the information is stored and the motor does not require the process for
subsequent run signals. In the event of system power loss exceeding 60 seconds, the rotation sensing
process is re-initiated at the next run signal after power is restored. If the motor is unable to sense the
proper rotation, the motor uses default rotation, which is counter-clockwise (CCW).
Electric Shock Hazard! The motor must be properly grounded through the furnace wiring harness.
Be careful when touching the exterior of an operating motor. It may be hot enough to cause serious injury.
This condition is normal for most motors when operated at rated load and voltage.
A motor should not be operated under conditions that cause the motor protection mode to run continually. A
motor that operates continually in motor protection mode may be overloaded, or the supply voltage or
frequency may be incorrect.
Actual operating speed is determined by the load applied. In general, if a motor is properly sized and
connected to its load, a detectable speed difference will be noted when different speed taps are energized.
When operating without a load, however, a motor will run continuously to a maximum speed and then stop
and restart operation.