8
Model FH94 Gas
III. OPERATION
FH94G
F. Gas Connection- 3/4” N.P.T.
At rated input the gas supply should deliver a minimum pressure of at least 15 mbar (6” water column) at the
broiler connection for natural gas. Incoming gas supply pressure must not exceed 50 mbar (14” water column).
1. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than
1/2 psi (3.45 kPa).
2. California Proposition 65 Notification: Public initiative Proposition 65 (1986) requires identification and
listing of certain chemicals known by the State to cause cancer or reproductive harm. Broiling meats
above flames or hot surfaces may produce chemicals that are on that list. If the concentrations of
chemicals on the products exceed the “safe harbor” limits, Proposition 65 requires restaurants to post a
warning to consumers in California restaurants.
G. Installing Gas Appliance Connectors and Flexible Gas Lines Correctly
For safety in the kitchen area, and to insure maximum service life, it is vitally important to correctly install
connectors. The connector shall comply with the Standard for Connectors for Moveable Gas Appliances, ANSI
Z21.69 or CAN/CGA-6.16 and a quick disconnect device that complies with the Standard for Quick-Disconnect
Devices for use with gas fuel, ANSI Z21.41 or CAN1-6.9
In order to avoid sharp kinks or excessive bends that could have a damaging effect on the connector, it may be
necessary to attach pipe elbows in order to bring the connector into its proper plane. For easy movement of the
appliance, the connector should be installed with a “lazy” loop for minimum tension.
Note: Gas appliances should be disconnected prior to maximum movement.
WARNING
If not installed, operated and maintained in
accordance with the manufacturer's instructions,
this product could expose you to substances in
fuel or from fuel combustion which can cause
cancer, birth defects or other reproductive harm.
Installation