10
PROBLEM
PROBABLE CAUSE
SOLUTION
9. Broiled product sticks to
conveyor belt.
10. Inconsistent broil.
11. Broiler frame or parts
warping.
1. Stripper blades not adjusted or installed
properly.
2. Product under broiled.
3. Elements too cool.
4. Heat reflectors not installed or installed
improperly.
1. Conveyor speed erratic.
2. Incoming product temperature erratic.
3. Air condition vent blowing on broiler.
4. Erratic voltage supply.
5. Supply voltage incorrect.
1. Elements too hot.
1. Adjust or install properly.
2. Decrease motor speed.
3. Check elements.
4. Refer to Parts & Location section for
proper placement of reflectors.
1. See #7 above.
2. Check freezers for proper operation.
3. Redirect air away from broiler.
4. Check supply. Contact electric company
if there are problems.
5. Match the supply voltage with the ele-
ment ratings.
1. Match supply voltage to element rating
plate on the broiler.