INTRODUCTION

  

 

Congratulations for buying one of the most innovative and easy to use Pocket Tester. 
 
Pocket testers series 1 and 5 are very handy for the routine measurements in all applications where 
fast indication of measurement is required. 
 
These  Testers  are  specially  designed  for  applications  like:  Agriculture,  water  and  waste  water 
treatment,  Hydroponics,  Aquaculture,  Environmental  monitoring,  Food  and  beverage 
manufacturing, Cooling towers, Printing, Education etc. 
 
Tester series 1 is basic one with fixed sensor and only two keys for all functions. 
 
Tester series 5 is advanced version with replaceable sensor, multicolour backlight display and 3 key 
for all functions. 
 
 

SAFETY INSTRUCTIONS 

  
 

       

Read this instruction manual carefully before using your new tester.  

 
       The membrane of pH electrode is made of glass and can be danger in case it breaks.  
       To avoid damage check the electrode tip after each measurements.  
 
       Replace all batteries together with the same type.  
 
       

The manufacturer of these instruments can’t be held responsible for any 

improper use.  

 
       Verification of the measuring results is the responsibility of the operator and the manufacturer  
       doesn

’t respond to any direct of indirect damage occurred while using this instrument.

  

 
  

DISPOSAL OF ELECTRONIC DEVICES 

 

The electrical and electronic equipment marked with this symbol cannot be 
disposed of in public landfills. 
According to the UE Directive 2002/96/EC, the European users of electrical 
and electronic equipment can return it to the dealer or manufacturer upon 
purchase of a new one. 
The illegal disposal of electrical and electronic equipment is punished with 
an administrative fine. 

 
 

 
 

Summary of Contents for EC2620

Page 1: ...USER MANUAL Testers EC2620 EC2630 EP2000 PH2620 PH2630 PH2720...

Page 2: ...PLY 6 INSTRUCTIONS FOR PH2620 pH1 EC2620 Cond1 7 POWER ON 7 POWER OFF 7 SETUP MENU for PH2620 pH1 EC2620 Cond1 7 MEASUREMENT 7 CALIBRATION PROCEDURE FOR CONDUCTIVITY EC2620 Cond1 8 CALIBRATION PROCEDU...

Page 3: ...TESTERS EC2620 EC2630 EP2000 PH2620 PH2630 PH2720 _____________________________________________________________________________________________ 3 PRODUCT SPECIFICATIONS...

Page 4: ...3 key for all functions SAFETY INSTRUCTIONS Read this instruction manual carefully before using your new tester The membrane of pH electrode is made of glass and can be danger in case it breaks To av...

Page 5: ...______________________________________________________________________ 5 PRODUCT DESCRIPTION KEYPAD PH2630 pH5 EC2630 Cond5 EP2000 PC5 PH2620 pH1 EC2620 Cond1 Keypad Functions for Tester PH2630 pH5 EC...

Page 6: ...CALIBRATION POINTS INDICATOR When a calibration is performed these icons indicate the points calibrated and First point for pH calibration is always 7 00 pH POWER SUPPLY This tester series works with...

Page 7: ...o select the parameter between COND or TDS to be used for measurements and press to confirm only for EC2620 Cond1 o Only if the TDS is selected then the display will show TDS FCT flashing press to cha...

Page 8: ...d solution CALIBRATION PROCEDURE FOR TDS EC2620 Cond1 When the meter is set to read TDS then the calibration is done on TDS with 1 or 2 points The calibration procedure for TDS is same as for Conducti...

Page 9: ...2630 Cond5 EP2000 PC5 1 With meter switched off press and hold CAL key and press key once 2 The meter will switch on with all the segments active release CAL key the meter will got into the Setup Menu...

Page 10: ...tandard value will flash for 3 times and then the meter will go into the measurement mode 8 If the 2nd point calibration is required then rinse the electrode with distilled water and immerse in the 2n...

Page 11: ...bration REPLACEMENT OF SENSOR Tester 5 series has replacement sensors which can be replaced in case it expires of damages 1 To replace the sensor unscrew the dial in anti clock wise 2 Pull out sensor...

Page 12: ...suring value is not stable during calibration Press key when icon appears During calibration the measuring value is not stable for 3min 1 Check whether there are bubbles in glass bulb 2 Replace with n...

Page 13: ......

Reviews: