Figure 7 : Diagram of the wiring system 220 V AC.

3.6. Gas system

Built-in cooker plate is designed for gas propane or butane under pressure range of 3000-4000 N/m².
Depending on a gassytem, the cooker plate can be equipped with distribution valve for a cooling box
connection.  The distribution valve, if exists, is located inside the kitchen cupboard.  The caravan 
should be equipped with a gas bottle and its pressure reducing valve, suitable to gas pressure of used
cooker.  The gas bottle compartment is suitable for two bottles each with a capacity of 2 or 5 kilograms
of gas.

In order to properly using the gas system, carry out following activities :
– screw on the pressure reducing valve on the gas bottle, until the fassteningnut reaches its properly
   tightness
– put on the bottle into its compartment
– safe the bottle against suddenly and unnecessary movements in the compartment, using clamps and
   flexible fastenings-belts
– put on the flexible hose on the nipple of the reducing valve and fit it with a clamping-ring
– open the valve of the bottle, the distribution valve, if any, choose the gas stream towards the cooker
– ignite the burner, it should be burn with a blue-violet coloured flame and a distinct core

If cooker is equipped with a flame safety device, carry out following activities :
– press the setting hand-wheel and turn it  on the maximal flame position
– ignite the burner until to the maximal flame
– hold the hand-wheel pressed for 15 seconds
– set require flame intensity
– try again, when flame has extinguished.

Check condition of the rubber hose regular and change it if the hose is damaged.
Notice that properly use of the cooker as well as reliable and properly condition of entire gas system
is effecting directly in safety use of the entire caravan.

Thus, on this reason, following is forbidden strictly :
– connecting any gas fed equipment without the gas pressure reducing valve to the bottle directly
– to use any leaky gas fed equipment for leaky gas distribution system
– opening the feeding valve of the cooling box when the box is leaky or opened
– mending or lingering on the gas distribution system or on the gas fed equipment to repair it yourself
– heating with the cooker flame the caravan living space
– to use the cooker by closed vent holes or blocked vent system of the caravan living space
– exchange burner nozzles yourself
– to use movable heaters fed on gas 

In case of fire : – evacuate all persons out of the caravan 
                          – close the main valve of the bottle and remove it out of the caravan
                          – fight the fire using the board extinguisher (available as a car obligatory equipment)
 

– call the fire  brigade

Suitable for this caravan purpose is the universal powder extinguisher.

Summary of Contents for Predom 126 D

Page 1: ...T H E C A R A V A N P R E D O M DESIGNS MANUAL FOR USE P r e d o m 126 D E ET P r e d o m 126 N NT NTL Fabryka Przyczep NIEWIADOW Sp z o o Poland 97 225 Ujazd tel 48 44 719 20 00 fax 48 44 719 21 61...

Page 2: ...assis maintenance 7 Care and small repairs Dear Customer Buying our Design N 126d or N 126e you have gained an advantage of famous caravan Familiarity with this manual will make you enjoy your caravan...

Page 3: ...extended rear views and two electricity connectors Ball diameter of the tow hook is 50 mm and the distance between the centre of the tow ball and the ground will be between 350 and 450 mm Both electri...

Page 4: ...between brake shoes and drum adjustment Turning the pin on according an arrow which is marked on a bracket effects in decreased gap between the brake shoes and the drum Adjustment of actuating rod fol...

Page 5: ...if necessary 3 Check damper condition of the overrunning 4 Check the return lever and its flexibility clean and smear it if necessary 3 3 Folded support The main task of the folded support is to keep...

Page 6: ...ed connect the plug of the transformer with the 12 V socket 8 of the caravan living space lighting located next to the left bed The net is protected with a fuse of 6 3 A located under a cover of the 1...

Page 7: ...grated connector 6 Living space lighting 12 Terminal 3 5 Wiring system 220 V AC This system is designed for use the electricity power with voltage of 220 V AC and is suitable for supply the equipment...

Page 8: ...ame safety device carry out following activities press the setting hand wheel and turn it on the maximal flame position ignite the burner until to the maximal flame hold the hand wheel pressed for 15...

Page 9: ...support up with folded supporting legs during the cold season support up the caravan with legs and reduce the air pressure For a wheel removing support up the caravan with the rear supporting legs an...

Page 10: ...eparture close firmly the hatch with cover and clamps safely its locks against surprised and unnecessary opening during the caravan towing 5 Recommended activities and handling before departure Carry...

Page 11: ...epair them with zinc spray 7 Care and small repairs After 50 km check tightness of every bolt nut and other threaded connection split collars conditions etc tight or change them if necessary Every 2 5...