background image

×

×

SPECIFICATIONS

ASSEMBLY (cont.)

HOW TO USE

PART NAMES, DIMENSIONS

WARNING

CARE & STORAGE NOTES

LED STAND MAGNIFIER 

4x Magnification lens SL-4
    Type : White Glass lens
    Magnification : ~4x
    Viewable diameter : ~

φ

140mm

Head : Polycarbonate
Base : Steel
~1.8m

Lens cloth, 3.0mm hex wrench 

Magnifying Lens

Material 

Cord Length
Accessories

  

Rated voltage
Rated freq.
Rated power 
Light source
Color temp. 
Efficiency
Weight
Height

AC100V
50/60Hz
15W
84x  white  LED
~5,000K

daylight

100lm/W
~5.3

~430mm

2x Magnification

Item No.:SL-2

Magnification:~2x

Viewable area:~

φ

170mm

Makes work easy - Hands free; Well lit; Wide view.

LS4-150S

Read and Follow for Safe Use of Product

BEFORE USE

Thank you for purchasing the LS4-150S LED Stand Magnifier.
Please read this manual thoroughly before use to insure proper operation and 
long service.

To prevent electrical shock, always make sure power is OFF before assembly or 

attaching/detaching lens or cleaning the equipment.

Never look at sun or bright light through the lens. There is risk of damage to eyesight.

Do not expose lens to sunlight or intense light, there is risk of starting fire.

Never leave lens in location where it can be exposed to direct or reflected sunlight. 

Close the lens cover when not in use in order to prevent starting fire.

When installed on a sloped surface the unit may slip causing malfunction, damage, or 

injury. Do not install on surface with incline of more than 5

°

 from horizontal.

Do not use the power cord for lifting or moving, and never pull on the cord. There is risk 

of the unit falling, or damage to the cord which may result in injury or fire.

CAUTION

Handle with Care. Do not drop, scratch, or use strong force with product. (Use special 

care when cleaning.) Damage to product may cause injury.

Do not wash the lens with water. Water in long contact with lens may cause mold or 

cloudiness.

The LED light is capable of frequent on/off cycles, but to avoid wear and damage to the 

switch, do not cycle the switch unnecessarily.

This product contains metal bearing surfaces and may produce trace amount of dust 

and powder due to repeated friction on metal surfaces. Therefore, it is not suitable for 

clean-room applications. If there is concern over exposing workpiece to contamination, 

do not use for that application or take care not to reposition light while above workpiece. 

Base Plate surface may scratch table if slid upon it. To prevent damage, place protective 

sheet or board under unit to protect the table.

Place workpiece on base plate, as moving the lens too far to the side may cause the 

light to topple. Do not forcibly move any parts beyond their limits and use care to prevent 

instability.

Please keep lens clean of dust and fingerprints.

Clean lens gently with dedicated lens cloth. Do not wash with abrasive cleaners, or rinse 

with water.

Keep lens protection cover in down position, and unplug power cord when not in use for 

extended period.

Instruction Manual

Niigata seiki Co., Ltd.

5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522   Fax. : +81-256-33-5518

MAIL   intl.sales@niigataseiki.co.jp

URL    http://www.niigataseiki.co.jp

Head Joint Range of Motion

Insert the Main Post all the way into the hole in the Support.

Secure with the Socket Head screw using the 3mm Hex Wrench.

Attach the Support Arm; make sure the Head Clamp is oriented 
pointed down as shown in the diagram.

Base

Support Arm

Main Post

Arm Clamp

socket head 

screw

3.0mm hex 

wrench

Head Clamp

Hole for Main Post

Main Post Support

Orientation

×

×

~

80

°

   max

~

30

°

   max

Horizontal

Vertical

Head Clamp

×

×

×

×

Never rotate the head toward 

the Support Arm beyond the 

center of Lens.

For best results, and to prevent 

eye fatigue, adjust the Arm so 

that the Lens is parallel to the 

surface you wish to inspect, 

and securely tighten the Clamp.

  

The best lens position will 

depend on distance between 
eyes and the workpiece.

Plug in the cord and turn on the 

Power Switch.

  

Position unit so that external 

lights, such as the ceiling 
fixtures, are not reflected in the 
lens.

After use, close the Lens 

Cover, turn off the Power 

Switch, and unplug the Power 

Cord.

Optional 

Replacement Lens:

Power 

Switch

approx. 280~410mm

Support Arm

Height : 430mm

Main Post Camp

Main Post

Power plug

Base
approx. : W240

×

D400mm

Lens Cover

Main Post 

Support

Light Head 

Clamp

Arm Clamp

Viewable area:

~

φ

140mm

Lens

Please Note: Due to product enhancements, appearance

and specifications are subject to change without notice.

ASSEMBLY INSTRUCTIONS

ASSEMBLY

CAUTION: Do not force the joint connecting the Light Head to the Support Arm 

beyond its range of motion. 

The joint will fail and create a hazardous condition

.

When first received, in order to avoid damage please use the following procedure 

to remove the Light Head from the box and assemble. 

Careful not to damage the cord, rotate the Support Arm horizontally 
in the direction of the arrow.

Be careful of the cord while removing from the box.

Move horizontally

It may cause damage

×

Do not lift arm up

Support Arm

Note, drawing omits ties, 
cord, etc. for clarity. Actual 
packaging may differ.

Video 

    demonstration!

https://youtu.be/
uUWNXm8rbmQ

Summary of Contents for LS4-150S

Page 1: ... unit to protect the table Place workpiece on base plate as moving the lens too far to the side may cause the light to topple Do not forcibly move any parts beyond their limits and use care to prevent instability Please keep lens clean of dust and fingerprints Clean lens gently with dedicated lens cloth Do not wash with abrasive cleaners or rinse with water Keep lens protection cover in down posit...

Page 2: ... 金属粉により観察物等にダメージが与えられる可能 性がある場合は 使用を中止するか観察物の上では可動部を動かさない等の異物 落下の防止対策をとってください 本体を動かした時に 机に傷が付くことがあります この場合はベースと机の間 にシートや板材を入れて傷を防止してください レンズ部を大きく左右に振った場合にレンズ部の重さで本体が倒れることがあり ます 観察物等はベース板の範囲内に置くようにしてください その他の可動部 も限界以上に無理に動かさないでください レンズ面に汚れ 指紋などをつけないようご注意ください レンズの清掃はレンズ専用布やガーゼで軽く拭く程度にしてください 研磨剤入 りの洗剤の使用や水洗いはしないでください 長時間使用しない時は 必ずレンズ保護カバーを閉め 差し込みプラグを電源か ら抜いてください 見やすく 目の疲れにくい位置 で レンズがなるべく観察物と 平行になるように...

Reviews: