X K 3 1 9 0
–
A26
()
15
①
Press"1"and "Clear"button in same time in weighing state.
Indicator display
【
bL
】
(
Power-saving mode chosen
)
【
*
】
Press
“
clear
”
enter into next optional function chosen.
②
Indicator display
【
Func
】
(
optional function chose
)
【
*
】
(
0~4
)
Now input
“
4
”
and choose upper and lower limit alarming optional function and
press "clear" confirm.
③
Indicator display
【
ctrL
】
(
Control method chosen
)
【
**
】
(
High and low 2 digits,and control 2 switch volume
output separately
)
Left digit control switch volume output 1, right digit control switch volume output
2, and control parameter 0~4 is selectable.
0
:
Not output
1
:
Greater than or equal the setting output
2
:
Less than the setting output
3
:
Greater than or equal the setting and stable output
4
:
Less than the setting output and stable output
After input the control method parameters,press"clear"confirm.
④
Indicator display
【
PP1
】
(
switch volume output 1 setting point
)
【
*****
】
Input the setting point and press"clear"confirm.
⑤
Indicator display
【
PP2
】
(
switch volume output 2 setting point
)
【
*****
】
Input the setting point and press"clear"confirm.And now finish the upper and
lower alarming parameter setting and back to weighing state.
<4>Application examples
a
、
For example: Switch 1 output is effective when weight is above 1.000kg and switch 2
output is effective when weight is above 2.000kg. Not judge stabilization.
Parameters : FunC =4
;
ctrL=11; PP1=1.000; PP2=2.000
。
b
、
For example:We need a switch output volume above1.900kg and under2.100kg
,
judge stabilization.