Parameters : FunC =4
;
ctrL=34; PP1=1.900; PP2=2.100
。
Now put the switch volume 1 and 2 together as hardware to be an output.
Chapter5 Information Indication
1. Err 03 :
Overload alarming, need remove parts of the load or all of the load.
2. Err 05 :
AD part fault, please examine and dispose as following
method
:
1.Examine load cell and its connecting wire.
2.AD part broken, please send back to factory for repairing.
3. Err 08 :
Parameter input is not meet the requirements, input parameter again
4. Err 09 :
Not meet the requirement of accumulation request :instable or no zero
operation.
5. Add :
Accumulating count, back to weighing state 3 seconds later
automatically.
6. totAL :
Accumulating display, automatically back to weighing state after 3
seconds.
.
7. InCodE :
Inner code display state,press“1”and “3”in same time to back to weighing state.