background image

X K 3 1 9 0 

A26 

() 

18

every time 20 to 25 hours.

 

(

Note

Charging time is around 20-25 hours and the indicator must be power off

When moving or installing the indicator, you must carefully move it and avoid 
strong vibration, impact or bump in order to avoid electrode in the battery being 
shorted and damaged 

10. Since invoice date, the indicator has a one-year free repair period. If any 

non-artificially failure happens under regular using conditions within this period, the user 

can send the indicator with its guarantee card (of the correct number) back to our service 

station or supplier for repair. The indicator shouldn’t be open without authorization , 

otherwise free guarantee will be cancelled.   

 

 

Summary of Contents for XK3190-A26

Page 1: ...1 XK3190 A26 Weighing Indicator U U Us s se e er r r M M Ma a an n nu u ua a al l l Version 1 01...

Page 2: ...4 Startup Zero operation and Manual zero operation 5 Tare operation 6 Unit price input 7 Accumulation clear and Accumulation display and accumulation clear 8 Saving and re call of unit price 9 Power...

Page 3: ...mV 9 Display Front side 5 5 6 digits LCD display white LED back light 4 state indication symbol 3 class battery power prompting Back side side 5 6 digits LCD display white LED back light 2 states indi...

Page 4: ...nstallation Connection 1 A26 weighing indicator front side function instruction and back side function instruction 2 1 1 Front side function instruction 2 1 2 Back side function instruction Fuse or ex...

Page 5: ...necting must be correct and reliable warning To ensure the system is working fine please fix the plug with screw to the indicator after the signal source wiring the user can not insert and pull out pl...

Page 6: ...all unit price Press two times store unit price 6 Zero button In Zero range The current gross weight as Zero Outside zero range no effect 7 On Off button Power off state Press button after 3 seconds p...

Page 7: ...will power off automatically 30 seconds later to protect the inside battery please use the indicator after charging 3 Working time A26 no back light One time charge can work around 180 hours typical...

Page 8: ...aces 2 Clear Method 1 2 seconds after unit price input press 0 button unit price clear to zero Method 2 If the indicator not in accu state accumulation indicate symbol is off press clear button unit p...

Page 9: ...dicator display SAVE unit price save reminder 0 Now press number button 0 9 to confirm the saving position indicator will be back to weighing state automatically after saving the data 2 Unit price cal...

Page 10: ...o power saving mode bL 3 Indicator is stable for 3 minutes and indicator will enter into power saving mode bL 4 Indicator always in power saving mode When bL 1 3 any button or weight changes will caus...

Page 11: ...ot 5 of the air plug on the back of the indicator is GND connect with the foot 5 of the computer 9 pin connector 3 Parameter setting Press 1 and Clear button in same time in weighing state Indicator d...

Page 12: ...to left 0 4 10 XOR checksum high 4 digit 11 XOR checksum low 4 digit 12 03 X0FF end The confirmation of higher 4 digits and lower 4 digits XOR checksum XOR checksum operated in 16 hex byte way from b...

Page 13: ...value including decimal point higher position Weighing data Weighing data 9 Weighing data low position For example the current display weight is 3 000 so the sending data is 0003 000 0003 000 0003 000...

Page 14: ...nt the weight bill After all the weighing press unit price button can print accumulate times and accumulate amount After print press accumulate clear button clear accumulate record and start the next...

Page 15: ...aper lines after every time print After enter the expected lines of run paper press the Clear button to confirm the indicator automatically returned to weighing state In the parameter input process pr...

Page 16: ...confirm and then enter to the next optional function chosen Indicator display DISP single window and three windows chosen 1 3 Now input single window 1 three windows 3 after chosen and press clear bu...

Page 17: ...ess than the setting output 3 Greater than or equal the setting and stable output 4 Less than the setting output and stable output After input the control method parameters press clear confirm Indicat...

Page 18: ...1 Examine load cell and its connecting wire 2 AD part broken please send back to factory for repairing 3 Err 08 Parameter input is not meet the requirements input parameter again 4 Err 09 Not meet the...

Page 19: ...ator damage caused by lightning strike ensure operators safety of weighing equipment and related equipment safety operation 4 Never use strong solvents e g benzene nitro class oil to clean the housing...

Page 20: ...avoid electrode in the battery being shorted and damaged 10 Since invoice date the indicator has a one year free repair period If any non artificially failure happens under regular using conditions wi...

Reviews: