X K 3 1 9 0
–
A26
()
5
Press
“
on/off tartup&shut down
”
button for 2~3 seconds in weighing state,then the
indicator will shut down.
3.
Battery use
(1)Battery charge
Indicator is turned off, connect the AC power (AC indication light is on), began to
charge the battery , the charging time is about 20 to 30 hours.
(2)Use
Start indicator without connection AC power, and the rechargeable battery inside the
indicator will supply the power to the indicator .
The indicator upper left indicates the remaining battery capacity, three grid means that
fully charged
;
two grid means capacity is not full
;
1 grid means capacity is low and need
connect to the AC power and charging at once
;
there is no grid means battery use out ,
the indicator will power off automatically 30 seconds later to protect the inside
battery ,please use the indicator after charging .
(3)Working time.
A26
(
no back light
)
One time charge can work around 180 hours
(
typical value
);
A26
(
with back light
)
One time charge can work around 36 hours
(
typical value
);
Start indicator with connection AC power, and the rechargeable battery inside will be
charged by AC power and the AC power will supply the indicator.
4.Start zero and manual zero
(1). Start zero
After self-test finished when start the indicator, if the loading of platform value is under
the full capacity 10%(relative to calibration zero point), the indicator automatically set to
zero, gross weight is displayed as 0.
(2)Manual zero
If the weight on the scale is under the full capacity 2% (relative to calibration zero point)
in weighing state,press
【
zero
】
key, you can put the current weight as the zero point,
gross weight is displayed as 0.