If the test is off and the button is pressed, the green LED will flash
and the red LED will come on for 2 seconds.
If the test is On and the button is pressed, the green LED will flash
for 2 seconds.
Lux On/Off:
Setting daylight-dependency.
Only works for App. 1 + 2.
If the movement sensor is daylight-dependent and the button is
pressed, the green LED will flash for 2 seconds. If the movement
sensor is daylight-independent and the button is pressed, the
green LED will flash and the red LED will come on for 2 seconds.
Reset:
Pressing this button restores all settings to factory settings.
For further information see the installation and user manual for
PIR Sensor model 350-20056.
3. OPERATION AND USE
App.:
Application, describes the function of the sensor.
Zones 1/2:
How the room is divided, see fig. 2.
Lux Zone 1/2:
Lux level where light is desired in zones 1/2.
Off delay:
Cut-off time before movement sensor switches off the
light.