Standard: Amplitude of all pulses/waveforms is 100mV or more.
Oscilloscope setting
V/Div(ch1)
100mV
V/Div(ch2)
100mV
Coupling
AC
Time/Div
1ms/div
Trigger Mode
NORMAL
Trigger Coupling
AC
Trigger Source
CH1
Trigger Position
+4div
Trigger Type
EDGE
Trigger Level
0V
INPUT(ch1)
AC
INPUT(ch2)
AC
4. How to inspect and adjust:
・
Confirm that the electric current and voltage of the connected rated voltage power-supply are set values
(5.0V, 100mA). then turn it ON.
・
Set the oscilloscope, and turn the MF ring unit (B26) with hand.
・
In case large waveform-noise is detected, use the FILTER function.
How to set FILTER function (e.g. DL1540 manufactured by YOKOGAWA)
①
Press the FILTER button.
②
Select "Smooth" of the menu on screen and turn it ON.
・
If there is no problem with the waveform of GMR sensor, remove the MF ring unit (B26). Then apply the
adhesive to the head of the two screws (#110) to fix.
If the amplitude of the waveform is less than 100mV, bend the head of the GMR sensor and make the
adjustment. Then, check the amplitude again.
#110×2
Caution: Check the waveform by rotating the MF ring unit (B26) all the way around back and forth.
Adhesive:Screwlock