・How to conduct inspection and adjustment
①
Make sure that the current and voltage of the connected rated voltage power supply are set values.
If they meet the set values, turn on the power.
②
Set the oscilloscope and drive the focus ring by hand.
Note:
Since the shape of waveform varies according to the driving speed of focus ring, particularly and properly set
Time/Div.
③
In case of detecting any wider waveform noise, use the filter function.
How to set the filer function in the employment case of Yokogawa-manufactured DL1540
1.
Press the filter button.
2.
Select "Smooth" in the menu on the PC screen.
●
Setting of oscilloscope
V/Div(CH1)
:20mV
V/Div(CH2)
:20mV
Coupling
:AC
Time/Div
:5m Sec
Trigger Mode
:NORMAL
Trigger Coupling
:AC
Trigger Source
:CH1
Trigger Position
:+4div
Trigger Type
:EDGE
Trigger Level
:0V
Standard:
The amplitude of every pulse/waveform should be 50mV or more.
Note:
Check the waveform by letting the focus ring to travel from the infinity-end position to
the near distance end position and vice versa.
C H 1 = 2 0 m V C H 2 = 2 0 m V 5 m s / d i v
A C 1 0 : 1 A C 1 0 : 1
NORM 200KS/s
Summary of Contents for AF-S Zoom-Nikkor ED 24-85mm f/3.5-4.5G IF
Page 8: ...JAA78071 R 3583 A L6 AF S 24 85 3 5 4 5G SWM UNIT 96 3 B31 96 3 SWM unit ...
Page 13: ...JAA78071 R 3583 A L11 AF S 24 85 3 5 4 5G CAM RING 50 50 ...
Page 24: ...JAA78071 R 3583 A L22 AF S 24 85 3 5 4 5G 96 3 3rd LENS GROUP 3rd lens group ...
Page 46: ...JAA78071 R 3583 A F1 AF S 24 85 3 5 4 5G 外観図 Sketch drawings ...
Page 47: ...JAA78071 R 3583 A F2 AF S 24 85 3 5 4 5G 組立図 Structure of the Lens ...