A-14 / ENGLISH
A-14
- FORM NO. 56091024 - PBU Propane Stripper
MAINTENANCE AND ADJUSTMENTS
Recommended 8 Hour Break In (50 hour there after) Maintenance Items -
>Change engine oil.
>Check pad driver for loose parts.
>Check belt for wear or slippage.
>Check engine pulley for tightness.
>Check wheel bolts.
>Check engine mount bolts.
>Check handle bolts.
>Check for leakage of engine oil at the various seals.
Recommended Oil Change Intervals
Do not exceed the oil change interval. Oil changes more frequent than 50 hours will give even longer engine life. In any case, always use 30HD or 10W30 engine
oil with all of the following API ratings: SJ or higher. Make sure the oil level is maintained at the “FULL” level.
Recommended 200 Hour Maintenance
Return machine to authorized service center for overall checkup.
The engine air intake
fi
lter must be changed every 200 hours.
>Check engine valve adjustment
CARB GARD OPERATION
Carb Gard is a warning device to alert the operator that the engine needs to be serviced.
1. Upon starting the engine, the GREEN “Alert” LED will begin
fl
ashing. It will continue
fl
ashing for 3 minutes. This allows the engine and the
oxygen sensor (mounted in the exhaust manifold) enough time to warm up. During this time, it is okay to operate the burnisher.
2. After 3 minutes, the Alert LED will stop
fl
ashing.
(a) If the engine is idling, then the YELLOW “Idle” LED will begin
fl
ashing. This allows the engine to idle for up to 2 minutes.
(b) After 2 minutes, the engine will shut down and the idle LED will remain solid to notify the operator why the machine shut down. (Note: If
this occurs, simply turn the key switch to OFF. This will reset the Carb Gard. Restart the engine normally to continue operation).
(c) If at any time before the 2 minute countdown, the engine is revved up to full throttle, the LED will stop
fl
ashing and the Carb Gard will
being monitoring the oxygen sensor.
(d) If the engine is allowed to slow back down to the idle position, the idle LED will again start
fl
ashing for another 2 minutes.
NOTE: Every time the engine is revved up and allowed to slow down, the 2 minute countdown restarts itself.
3. Once the engine is revved up, the Carb Gard begins monitoring the oxygen sensor for carbon monoxide (CO).
(a) If at any time during full throttle the Carb Gard senses a higher than normal CO output, it will activate the RED “Service” LED and it will
begin
fl
ashing.
(b) If the RED service LED
fl
ashes continuously for 1 minute, then the engine will shut down and the RED service LED will remain solid to
notify the operator why the engine shut down.
NOTE: Carb Gard continuously monitors CO output. If the CO output drops, the service LED will stop
fl
ashing. If the CO output rises, it will
start
fl
ashing again. ONLY after it continuously
fl
ashes for 1 minute will it shut down the engine.
Summary of Contents for 21KBCAT
Page 44: ...Propane Floor Stripper Equipment Parts Manual ...
Page 45: ...FORM NO 56091024 PBU STRIPPER 10 10 P 2 BASE SYSTEM ...
Page 47: ...FORM NO 56091024 PBU STRIPPER 10 10 P 4 STRIPPER SYSTEM ...
Page 49: ...FORM NO 56091024 PBU STRIPPER 10 10 P 6 DECAL SYSTEM ...
Page 51: ...FORM NO 56091024 PBU STRIPPER 10 10 P 8 ELECTRICAL SYSTEM ...
Page 53: ...FORM NO 56091024 PBU STRIPPER 10 10 P 10 ENGINE SYSTEM ...
Page 59: ......
Page 62: ......
Page 63: ......
Page 64: ...Nilfisk Advance Inc Plymouth MN 55447 3408 2011 ...