Service Manual-AS1050R
04 Control System 25
4.
“Error 4”:
Traction motor short circuit or overload
•
Possible causes:
•
1. Traction motor or Main Controller (EB2) or wiring short circuit.
•
2. Physical resistance to machine movement such as a dragging brake or going up a steep incline.
5.
“Error 5”:
Brush actuator motor short circuit or overload
•
Possible causes:
•
1. Brush actuator motor or Main Controller (EB2) or wiring short circuit.
•
2.Physical resistance to deck raising or lowering.
6.
“Error 6”:
Low battery voltage
•
Check battery voltage.
•
Charge battery.
7.
“Error 7”:
Brush motor wiring open circuit
•
Check wire harness in
brush motor and
Main Controller (EB2)
.
•
Check circuit breaker (F3, F4).
•
Check
brush motor.
Traction motor
Main Controller (EB2)
Brush actuator motor
Main Controller (EB2)