Service Manual-
AS1050R
24 Electrical System 57
24 Electrical System
Functional Description
The batteries (3 x 12V or 6 x 6V) are connected in series.
When an external charger is inserted, charger sensor switch (SW3) will close. If key switch is on at this time, LCD will
be off. And at the same time Main Controller (EB2) will disconnect K1 and prevent any output. When charger is inserted
to charge for more than 2 hours or battery voltage is more than 38V, LCD will display full battery power status in battery
power icon after unplugging charger and turning on key switch.
The emergency switch (SW1) and key switch (SW2) are connected in series, which are used to power Dash Board
(EB1) and Main Controller (EB2). When one of the switches is opened, all machine functions will be disabled.
Only when both the key switch (SW2) and emergency switch (SW1) are switched on can USB charger (EB3) charge
the phone.
To prolong battery lifespan, the machine has low voltage cut-off function. When battery voltage is low, the battery
power icon on LCD flashes to remind operator to charge.
Brush motor and vacuum motor can’t work normally until the
battery is fully charged and the battery power icon displays full battery power status.
Different battery type settings are of different low voltage cut-off thresholds. See corresponding voltage values in table
below. If the type of battery is changed, the battery type parameter must be updated. See section
“Parameter Setting
Without Password” (on page 44).
Battery Type
WET
GEL
AGM
DIS-EV
ENE
LVC Voltage (V)
30.6
32.4
32.4
34.2
34.0
Summary of Contents for 50000593
Page 11: ...Service Manual AS1050R 03 General Information 11 Machine Structure Figure 2 ...
Page 12: ...Service Manual AS1050R 03 General Information 12 Machine Structure continues Figure 3 ...
Page 13: ...Service Manual AS1050R 03 General Information 13 Control Panel Figure 4 ...
Page 15: ...Service Manual AS1050R 03 General Information 15 Dimensions continues ...