Service Manual-
AS1050R
30 Solution System 72
30 Solution System
Functional Description
The solution system supplies water to the brush when
cleaning the floor. The solution tank is also the main
body. The manual valve on the left side of the tank is
to close water supply when performing maintenance.
The solution flows from tank to tap, through the filter
and solenoid valve (EV1) and then to brush deck.
The water pump (M8) and solution valve (EV1) can only
operate when all following inputs/conditions are met:
Brush function is enabled
The throttle pedal is pressed
Battery capacity >10%
Solution sensor (SW4) is not activated
Wiring Diagram
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
D
D
C
C
B
B
A
A
TIGER3 Solution System
EB2
BLK
BAT+
BAT-
+36V Input
B-
RED
PUR
EB1
P3-18
P4-2
P4-3
P1-1
P1-4
P1-2
P1-3
CAN H
CAN L
CAN H
CAN L
EV1
Solution Valve
P2-8
P2-9
RED
BRN
WHI
Main Controller
Solution Sensor
C8-1
C8-2
BN/BK
P3-2
BLK
BLK
SW4
M
M8
Water Pump
C11-1
C11-2
Dash Board
BN/BK
VCC
GND
Key Switch
BLK
PUR
P2-1
P2-2
BLK
BLK
GRN
RED
BAT-
BAT+
120 Ohm
120 Ohm
+20V
+36V Out
+36V Out
B-
B-
Figure 1
Summary of Contents for 50000593
Page 11: ...Service Manual AS1050R 03 General Information 11 Machine Structure Figure 2 ...
Page 12: ...Service Manual AS1050R 03 General Information 12 Machine Structure continues Figure 3 ...
Page 13: ...Service Manual AS1050R 03 General Information 13 Control Panel Figure 4 ...
Page 15: ...Service Manual AS1050R 03 General Information 15 Dimensions continues ...