34 Scrub System 80
Brush Deck Actuator System
The brush deck actuator (M6) is controlled directly by the Main Controller (EB2).
When the machine is turned on the actuator is powered to move upwards for several seconds until the cam on the
actuator opens the travel limit switch, giving it time to reach the fully retracted position. Once the travel limit switch is
opened, the controller can identify that the actuator has reached this position, which is also defined as the home
position.
When brush pressure function is enabled, brush deck actuator (M6) will descend to the position of the selected brush
pressure level. There are 3 brush pressure levels in total. Operators can select them via Dash Board (EB1). Different
levels of brush pressure are achieved by controlling the electrifying time for the brush deck actuator (M6) to extend
from home position to the position of selected brush pressure level, which is irrelevant to brush motor amperage. It
is also achieved by preset electrifying time when pressure level is changed from level 1 to level 2.