Service Manual-
AS1050R
34 Scrub System 87
Troubleshooting
Trouble
Possible causes
Remedy
Brush does not clean
properly
Brush is excessively worn
Replace
Only one brush can rotate
Brush motor carbon brushes worn
Replace
Presence of mass debris or strings around
brush or between brush and attachment
flange
Remove brush and clean it
Brush motor damaged
Repair/replace
Wiring damaged
Repair
Circuit breaker (F3 or F4) is opened
Reset circuit breaker
Can’t raise/lower the brush
Brush deck actuator overloaded
Check if brush deck actuator is stuck
Brush deck actuator (M5) damaged
Replace
Wiring damaged
Repair/replace
Main Controller (EB2) damaged
Repair/replace
Circuit breaker (F7) is opened
Reset circuit breaker
The brush disengagement
system does not work
Main Controller (EB2) damaged
Repair/replace
Wiring damaged
Repair/replace
Circuit breaker (F3 or F4) is opened
Reset circuit breaker