background image

8/03 revised  7/13  Form No. 56040800 REV D

© 2013 Nil

fi

 sk-Advance, Inc. 

(page 4 of 7)

 

Condor XL / ER1300, ER1600 INSTALLATION INSTRUCTIONS

 WARNING!

TURN KEY OFF BEFORE SERVICING.

5

 

See Figure 4.

  Open the engine cover and locate the part of the frame where the back-up alarm will mount using the pre-drilled holes.  

NOTE:

  

The backup alarm mounts just to the left of the squeegee lift cylinder.

6

 

Mount the Back-Up Alarm 

(A)

 to the frame as shown using Screws 

(D)

 and Washers 

(F)

.

7

 

Locate the Wire Connector from the main wiring harness next to the hydraulic reservoir.  The connector will have one GRN/BRN and one BLU/
BLK wire going to it.  Plug in the alarm harness to this connector.

FIGURE 4

8

 

Proceed to Page 6 for programming instructions.  After programming, 
close the engine cover.  Start the machine and test the back-up alarm 
for proper operation.
The alarm should sound in reverse only.

A

D

F

Summary of Contents for 56305519

Page 1: ...re Assembly Pigtail C 56409538 2 Terminal Insulator D 56009018 2 Scr Hex Thd Form 1 4 20 x 75 E 56002708 2 Nut Hex Nyl Loc 1 4 20 F 56002098 2 Washer Flat Not Shown 1 See Figure 1 Slide one Terminal I...

Page 2: ...he frame as shown using Screws D and Washers F 7 Locate the Connector from the main harness that will be located near the mounting location of the Back up Alarm A The connector will have one GRN BRN a...

Page 3: ...ppear on the Display Screen 3 3B Use the Scrub Pressure Increase 3E and Scrub Pressure Decrease 3H buttons to scroll through the menus until Back up Alarm Installed appears Press the One Touch Scrub b...

Page 4: ...to the left of the squeegee lift cylinder 6 Mount the Back Up Alarm A to the frame as shown using Screws D and Washers F 7 Locate the Wire Connector from the main wiring harness next to the hydraulic...

Page 5: ...OFF BEFORE SERVICING 5 See Figure 5 Open the engine cover and locate the part of the frame where the back up alarm will mount using the pre drilled holes NOTE The backup alarm mounts just to the right...

Page 6: ...able options 3 Once you see the appropriate option on the Display Panel D press the Scrub ON Switch G to enter the sub menu for that option 4 Once in the option sub menu press the Side Broom Raise E o...

Page 7: ...kwise Set the panel aside 7 Mount the back up alarm to the frame as shown using Screws D Washers F and Nuts E 8 Locate the Wire Connector K from the main wiring harness behind where the rear panel was...

Reviews: