Condor XL / ER1300, ER1600 INSTALLATION INSTRUCTIONS
WARNING!
TURN KEY OFF BEFORE SERVICING.
5
See Figure 4.
Open the engine cover and locate the part of the frame where the back-up alarm will mount using the pre-drilled holes.
NOTE:
The backup alarm mounts just to the left of the squeegee lift cylinder.
6
Mount the Back-Up Alarm
(A)
to the frame as shown using Screws
(D)
and Washers
(F)
.
7
Locate the Wire Connector from the main wiring harness next to the hydraulic reservoir. The connector will have one GRN/BRN and one BLU/
BLK wire going to it. Plug in the alarm harness to this connector.
FIGURE 4
8
Proceed to Page 6 for programming instructions. After programming,
close the engine cover. Start the machine and test the back-up alarm
for proper operation.
The alarm should sound in reverse only.