ENGLISH / A-17
Adhancer
™
R28-C, R32-C / BR 800S TRIO EDS
™
- 56041647 -
A-17
GENERAL MACHINE TROUBLESHOOTING
Problem
Possible Cause
Remedy
Poor water pick-up
Worn or torn squeegee blades
Reverse or replace
Squeegee out of adjustment
Adjust so blades touch
fl
oor evenly
across entire width
Recovery tank full
Empty recovery tank
Recovery tank drain hose leak
Secure drain hose cap or replace
Recovery tank cover gasket leak
Replace gasket / Seat cover properly
Debris caught in squeegee
Clean squeegee tool
Vacuum hose clogged
Remove debris
Using too much solution
Adjust solution control valves
Foam
fi
lter cover not seated
Seat cover properly
Poor scrubbing performance
Worn brush
Rotate or replace brushes
Wrong brush type
Consult Nil
fi
sk-Advance
Wrong cleaning chemical
Consult Nil
fi
sk-Advance
Moving machine too fast
Slow down
Not using enough solution
Adjust solution
fl
ow rate to high
fl
ow
Inadequate solution
fl
ow
or no solution
Solution tank empty
Fill solution tank
Solution lines, valves,
fi
lter or trough clogged
Flush lines, trough and clean solution
fi
lter
Solution valve not open
Open solution valve
Solution solenoid valve
Clean or replace valve
Machine does not run
Emergency stop switch tripped
Reconnect battery connectors
Operator seat safety switch
Check for open circuit and replace
Main system controller
Check error fault codes
(see service manual)
Tripped 10 Amp circuit breaker
Check for electrical short circuit & reset
No FWD/REV wheel drive
Drive system speed controller
Check error fault codes
(see service manual)
Tripped 45 Amp
circuit breaker
Check for drive motor overload
Emergency stop switch tripped
Reconnect battery connectors
Vacuum shuts off and display shows
“FULL” when recovery tank is not full
Plugged squeegee hose
Clear debris
Vacuuming large amounts of water
at a high travel speed
Slow down or disable auto shut-off feature
(see service manual)
Poor Sweeping Performance
Hopper Full
Empty and clean hopper
Brushes worn
Replace brushes
Bristles have taken a set
Rotate brushes
No Detergent Flow
Empty detergent cartridge
Fill detergent cartridge
Plugged or kinked detergent
fl
ow line
Purge system, straighten lines to
remove any kinks
Dry seal cap on detergent cartridge not sealed
Reseat dry seal cap
Detergent pump wiring
disconnected or backwards
Connect or reconnect wiring
Summary of Contents for 56316025 (R32-C)
Page 19: ......